This folder contains the sinks for the cc-metric-collector.
# `sink.go`
The base class/configuration is located in `sink.go`.
# Sinks
There are currently two sinks shipped with the cc-metric-collector:
* `stdoutSink.go`: Writes all metrics to `stdout` in InfluxDB line protocol. The sink does not use https://github.com/influxdata/line-protocol to reduce the executed code for debugging
* `influxSink.go`: Writes all metrics to an InfluxDB database instance using a blocking writer. It uses https://github.com/influxdata/influxdb-client-go . Configuration for the server, port, user, password and database name are in the global configuration file
* `natsSink.go`: Sends all metrics to an NATS server using the InfluxDB line protocol as encoding. It uses https://github.com/nats-io/nats.go . Configuration for the server, port, user, password and database name are in the global configuration file. The database name is used as subject for the NATS messages.
# Installation
Nothing to do, all sinks are pure Go code
# Contributing own sinks
A sink contains three functions and is derived from the type `Sink` (in `sink.go`):
* `Init(host string, port string, user string, password string, database string) error`
* `Write(measurement string, tags map[string]string, fields map[string]interface{}, t time.Time) error`
* `Close()`
The data structures should be set up in `Init()` like opening a file or server connection. The `Write()` function takes a measurement, tags, fields and a timestamp and writes/sends the data. The `Close()` function should tear down anything created in `Init()`.