title: Lenovo Dense Power collector
description: Collect power of Lenovo Dense machines using ipmitool raw
categories: [cc-metric-collector]
tags: ['Admin']
weight: 2
hugo_path: docs/reference/cc-metric-collector/collectors/lenovoDensePower.md
---
-->
## `lenovo_dense_power` collector
```json
"lenovo_dense_power": {
"ipmitool_path": "/path/to/ipmitool",
"use_sudo": true,
"include_metrics" : []
}
```
The `lenovo_dense_power` collector reads power from Lenovo Dense machines via `ipmitool` (`ipmitool raw ...`). This collector is known to only work on the following machines. Others are not supported, so use at your *OWN* risk:
System | Compatibility | Power measured
--- | --- | ---
Lenovo ThinkSystem SD650 V2/V3 | untested, but should work | node + riser1 + riser2
Lenovo ThinkSystem SD650-N V2/ SD650-I V3 | untested, but should work | node + riser1 + riser2 + gpus
Lenovo ThinkSystem SD665-N V3 | tested, known to work | node + riser1 + riser2 + gpus
To test if your system *may* be supported, you can run the following command *at your own risk*:
```
ipmitool raw 58 50 4 2 0 0 0
```
`ipmitool` typically require root to run.
In order to run `cc-metric-collector` without root priviliges, you can enable `use_sudo`.
Add a file like this in `/etc/sudoers.d/` to allow `cc-metric-collector` to run the required commands:
```
# Do not log the following sudo commands from monitoring, since this causes a lot of log spam.
# However keep log_denied enabled, to detect failures
Defaults: monitoring !log_allowed, !pam_session
# Allow to use ipmitool for Lenovo power readings
monitoring ALL = (root) NOPASSWD:/usr/bin/ipmitool raw 58 50 4 2 0 0 0
```