* Use channels, add a metric router, split up configuration and use extended version of Influx line protocol internally * Use central timer for collectors and router. Add expressions to router * Add expression to router config * Update entry points * Start with README * Update README for CCMetric * Formatting * Update README.md * Add README for MultiChanTicker * Add README for MultiChanTicker * Update README.md * Add README to metric router * Update main README * Remove SinkEntity type * Update README for sinks * Update go files * Update README for receivers * Update collectors README * Update collectors README * Use seperate page per collector * Fix for tempstat page * Add docs for customcmd collector * Add docs for ipmistat collector * Add docs for topprocs collector * Update customCmdMetric.md * Use seconds when calculating LIKWID metrics * Add IB metrics ib_recv_pkts and ib_xmit_pkts * Drop domain part of host name * Updated to latest stable version of likwid * Define source code dependencies in Makefile * Add GPFS / IBM Spectrum Scale collector * Add vet and staticcheck make targets * Add vet and staticcheck make targets * Avoid go vet warning: struct field tag `json:"..., omitempty"` not compatible with reflect.StructTag.Get: suspicious space in struct tag value struct field tag `json:"...", omitempty` not compatible with reflect.StructTag.Get: key:"value" pairs not separated by spaces * Add sample collector to README.md * Add CPU frequency collector * Avoid staticcheck warning: redundant return statement * Avoid staticcheck warning: unnecessary assignment to the blank identifier * Simplified code * Add CPUFreqCollectorCpuinfo a metric collector to measure the current frequency of the CPUs as obtained from /proc/cpuinfo Only measure on the first hyperthread * Add collector for NFS clients * Move publication of metrics into Flush() for NatsSink * Update GitHub actions * Refactoring * Avoid vet warning: Println arg list ends with redundant newline * Avoid vet warning struct field commands has json tag but is not exported * Avoid vet warning: return copies lock value. * Corrected typo * Refactoring * Add go sources in internal/... * Bad separator in Makefile * Fix Infiniband collector Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
51 lines
1.5 KiB
Markdown
51 lines
1.5 KiB
Markdown
# CC Metric Router
|
|
|
|
The CCMetric router sits in between the collectors and the sinks and can be used to add and remove tags to/from traversing [CCMetrics](../ccMetric/README.md).
|
|
|
|
# Configuration
|
|
|
|
```json
|
|
{
|
|
"add_tags" : [
|
|
{
|
|
"key" : "cluster",
|
|
"value" : "testcluster",
|
|
"if" : "*"
|
|
},
|
|
{
|
|
"key" : "test",
|
|
"value" : "testing",
|
|
"if" : "name == 'temp_package_id_0'"
|
|
}
|
|
],
|
|
"delete_tags" : [
|
|
{
|
|
"key" : "unit",
|
|
"value" : "*",
|
|
"if" : "*"
|
|
}
|
|
],
|
|
"interval_timestamp" : true
|
|
}
|
|
```
|
|
|
|
There are three main options `add_tags`, `delete_tags` and `interval_timestamp`. `add_tags` and `delete_tags` are lists consisting of dicts with `key`, `value` and `if`. The `value` can be omitted in the `delete_tags` part as it only uses the `key` for removal. The `interval_timestamp` setting means that a unique timestamp is applied to all metrics traversing the router during an interval.
|
|
|
|
# Conditional manipulation of tags
|
|
|
|
The `if` setting allows conditional testing of a single metric like in the example:
|
|
|
|
```json
|
|
{
|
|
"key" : "test",
|
|
"value" : "testing",
|
|
"if" : "name == 'temp_package_id_0'"
|
|
}
|
|
```
|
|
|
|
If the CCMetric name is equal to 'temp_package_id_0', it adds an additional tag `test=testing` to the metric.
|
|
|
|
In order to match all metrics, you can use `*`, so in order to add a flag per default, like the `cluster=testcluster` tag in the example.
|
|
|
|
|