SNMP Receiver

  "<name>": {
    "type": "snmp",
    "read_interval": "30s",
    "targets" : [{
        "hostname" : "host1.example.com",
        "port" : 161,
        "community": "public",
        "timeout" : 1,
    }],
    "metrics" : [
        {
            "name": "sensor1",
            "value": "1.3.6.1.2.1.1.4.0",
            "unit": "1.3.6.1.2.1.1.7.0",
        },
        {
            "name": "1.3.6.1.2.1.1.2.0",
            "value": "1.3.6.1.2.1.1.4.0",
            "unit": "mb/s",
        }
    ]
  }

The snmp receiver uses gosnmp to read metrics from network-attached devices.

The configuration of SNMP is quite extensive due to it's flexibility.

Configuration

  • type has to be snmp
  • read_interval as duration like '1s' or '20s' (default '30s')

For the receiver, the configuration is split in two parts:

Target configuration

Each network-attached device that should be queried. A target consits of

  • hostname
  • port (default 161)
  • community (default public)
  • timeout as duration like '1s' or '20s' (default '1s')
  • version SNMP version X (X in 1, 2c, 3) (default 2c)
  • type to specify type tag for the target (default node)
  • type-id to specify type-id tag for the target
  • stype to specify stype tag (sub type) for the target
  • stype-id to specify stype-id tag for the target

Metric configuration

  • name can be an OID or a user-given string
  • value has to be an OID
  • unit can be empty, an OID or a user-given string

If a OID is used for name or unit, the receiver will use the returned values to create the output metric. If there are any issues with the returned values, it uses the OID.