mirror of
				https://github.com/ClusterCockpit/cc-metric-collector.git
				synced 2025-11-04 10:45:06 +01:00 
			
		
		
		
	
		
			
				
	
	
	
		
			1.8 KiB
		
	
	
	
	
	
	
	
			
		
		
	
	
			1.8 KiB
		
	
	
	
	
	
	
	
nfsiostat collector
  "nfsiostat": {
    "exclude_metrics": [
      "oread", "pageread"
    ],
    "exclude_filesystems": [
      "/mnt"
    ],
    "use_server_as_stype": false,
    "send_abs_values": false,
    "send_derived_values": true
  }
The nfsiostat collector reads data from /proc/self/mountstats and outputs a handful node metrics for each NFS filesystem. If a metric or filesystem is not required, it can be excluded from forwarding it to the sink. Note: When excluding metrics, you must provide the base metric name (e.g. pageread) without the nfsio_ prefix. This exclusion applies to both absolute and derived values.
Metrics:
nfsio_nread: Bytes transferred by normalread()callsnfsio_nwrite: Bytes transferred by normalwrite()callsnfsio_oread: Bytes transferred byread()calls withO_DIRECTnfsio_owrite: Bytes transferred bywrite()calls withO_DIRECTnfsio_pageread: Pages transferred byread()callsnfsio_pagewrite: Pages transferred bywrite()callsnfsio_nfsread: Bytes transferred for reading from the servernfsio_nfswrite: Pages transferred by writing to the server
For each of these, if derived values are enabled, an additional metric is sent with the _bw suffix, which represents the rate:
- For normal byte metrics: 
unit=bytes/sec - For page metrics: 
unit=4K_pages/s 
The nfsiostat collector adds the mountpoint to the tags as stype=filesystem,stype-id=<mountpoint>. If the server address should be used instead of the mountpoint, use the use_server_as_stype config setting.