README.md |
Overview
ClusterCockpit uses the InfluxData line-protocol for transferring metrics and events between its components. The line-protocol is a text-based representation of a metric/event with a value, time and describing tags. All metrics/events have the following format (if written to stdout
):
<measurement>,<tag set> <field set> <timestamp>
where <tag set>
and <field set>
are comma-separated lists of key=value
entries. In a mind-model, think about tags as indices
in the database for faster lookup and the <field set>
as metric/event values. The <measurement>
is here used as "identifier" because it does not represent a "measurement" in all cases.
Line-protocol in the ClusterCockpit ecosystem
In ClusterCockpit we limit the flexibility of the InfluxData line-protocol slightly. The idea is to keep the format evaluatable by different components.
Each metric is identifiable by the measurement
(= metric name), the hostname
, the type
and, if required, a type-id
.
Mandatory tags per message:
hostname
type
node
socket
die
memoryDomain
llc
core
hwthread
accelerator
type-id
for further specifying the type like CPU socket or HW Thread identifier
Although no type-id
is required if type=node
, it is recommended to send type=node,type-id=0
.
Optional tags depending on the message:
In some cases, optional tags are required like filesystem
, device
or version
. While you are free to do that, the ClusterCockpit components in the stack above will recognize stype
(= "sub type") and stype-id
. So filesystem=/homes
should be better specified as stype=filesystem,stype-id=/homes
Mandatory fields per measurement:
The field key is always value
. No other field keys are evaluated by the ClusterCockpit ecosystem.
Message types
There exist different message types in the ClusterCockpit ecosystem.
Metrics
Identification: value=X
with X
being a number
While the measurements (metric names) can be chosen freely, there is a basic set of measurements which should be present as long as you navigate in the ClusterCockpit ecosystem
flops_sp
: Single-precision floating point rate inFlops/s
flops_dp
: Double-precision floating point rate inFlops/s
flops_any
: Combined floating point rate inFlops/s
(often(flops_dp * 2) + flops_sp
)cpu_load
: The 1m load of the system (see/proc/loadavg
)mem_used
: The amount of memory used by applications (see/proc/meminfo
)ipc
: instructions-per-cycle metricmem_bw
: Main memory bandwidth (read and write) inMByte/s
cpu_power
: Power consumption of the whole CPU packagemem_power
: Power consumption of the memory subsystemclock
: CPU clock inMHz
- ...
For the whole list, see job-data schema
Events
Identification: value="X"
with "X"
being a string
Controls
Identification: method
tag is either GET
or PUT