mirror of
https://github.com/ClusterCockpit/cc-specifications.git
synced 2024-12-26 05:19:05 +01:00
Merge branch 'master' of github.com:ClusterCockpit/cc-specifications
This commit is contained in:
commit
07a3eec1ef
@ -8,7 +8,7 @@ data.
|
||||
```
|
||||
|
||||
Supported measurements:
|
||||
* node – Tags: host, cpu
|
||||
* node – Tags: host
|
||||
* socket – Tags: host, socket
|
||||
* cpu -- Tags: host, cpu
|
||||
|
||||
|
55
metrics/lineprotocol_alternative.md
Normal file
55
metrics/lineprotocol_alternative.md
Normal file
@ -0,0 +1,55 @@
|
||||
# Overview
|
||||
|
||||
ClusterCockpit uses the InfluxData line-protocol for collecting the node metric
|
||||
data.
|
||||
|
||||
```
|
||||
<measurement>,<tag set> <field set> <timestamp [s]>
|
||||
```
|
||||
|
||||
**Note**: This is a proposal for a different way to send & store the data!
|
||||
|
||||
# Supported measurements:
|
||||
* `flops_sp`
|
||||
* `flops_dp`
|
||||
* `flops_any`
|
||||
* `load`
|
||||
* `mem_used`
|
||||
* `ipc`
|
||||
* `mem_bw`
|
||||
* `power`
|
||||
* `clock`
|
||||
* ...
|
||||
|
||||
# Mandatory tags per measurement:
|
||||
* `hostname`
|
||||
* `type` in `[node, socket, cpu, (accelerator)]`
|
||||
* `type-id` for further specifying the type like CPU socket or HW Thread identifier
|
||||
|
||||
# Optional tags depending on the measurment:
|
||||
* `device` for measurement `file_bw`
|
||||
* `device` for `net_bw` if splitting into `ib_bw` and `eth_bw` is not enough
|
||||
|
||||
# Fields per measurement:
|
||||
The field key is always `value`
|
||||
|
||||
# Optional measurements:
|
||||
If a fixed aggregation to a coarser granularity is desired, add addtional measurments to the same measurement with different tags:
|
||||
```
|
||||
mem_bw,hostname=X,type="socket",type-id=0 value=100.0
|
||||
mem_bw,hostname=X,type="socket",type-id=1 value=200.0
|
||||
```
|
||||
|
||||
can additionally be send/stored as:
|
||||
|
||||
```
|
||||
mem_bw,hostname=X,type="node",type-id=0 value=300.0
|
||||
```
|
||||
|
||||
It is discussable where the type of aggregation should be encoded if required, either by adding a tag like `agg={min,max,sum,avg}` or using different fields like:
|
||||
|
||||
```
|
||||
mem_bw,hostname=X,type="node",type-id=0 sum=300.0,min=100.0,max=200.0,avg=150.0
|
||||
```
|
||||
|
||||
I prefer the separate `agg` tag because commonly, only a single type of aggregation is done per measurment (mostly `sum` but some require `avg` like `ipc`)
|