Thomas Gruber bd04e19c96
Merge development branch to main (#141)
* Remove go-toolkit as build requirement for RPM builds if run in CI

* Remove condition around BuildRequires and use go-toolkit for RPM builds

* use go-toolkit for RPM builds

* Install go-toolkit to fulfill build requirements for RPM

* Add golang-race for UBI9 and Alma9

* Fix wrongly named packages

* Fix wrongly named packages

* Fix Release part

* Fix Release part

* Fix documentation of RAPL collector

* Mark all JSON config fields of message processor as omitempty

* Generate HUGO inputs out of Markdown files

* Check creation of CCMessage in NATS receiver

* Use CCMessage FromBytes instead of Influx's decoder

* Rename 'process_message' to 'process_messages' in metricRouter config

This makes the behavior more consistent with the other modules, which
have their MessageProcessor named 'process_messages'. This most likely
was just a typo.

* Add optional interface alias in netstat (#130)

* Check creation of CCMessage in NATS receiver

* add optional interface aliases for netstatMetric

* small fix

---------

Co-authored-by: Thomas Roehl <thomas.roehl@fau.de>
Co-authored-by: exterr2f <Robert.Externbrink@rub.de>
Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com>

* Fix excluded metrics for diskstat and add exclude_mounts (#131)

* Check creation of CCMessage in NATS receiver

* fix excluded metrics and add optional mountpoint exclude

---------

Co-authored-by: Thomas Roehl <thomas.roehl@fau.de>
Co-authored-by: exterr2f <Robert.Externbrink@rub.de>
Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com>

* Add derived values for nfsiostat (#132)

* Check creation of CCMessage in NATS receiver

* add derived_values for nfsiostatMetric

---------

Co-authored-by: Thomas Roehl <thomas.roehl@fau.de>
Co-authored-by: exterr2f <Robert.Externbrink@rub.de>
Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com>

* Add exclude_devices to iostat (#133)

* Check creation of CCMessage in NATS receiver

* add exclude_device for iostatMetric

* add md file

---------

Co-authored-by: Thomas Roehl <thomas.roehl@fau.de>
Co-authored-by: exterr2f <Robert.Externbrink@rub.de>
Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com>

* Add derived_values for numastats (#134)

* Check creation of CCMessage in NATS receiver

* add derived_values for numastats

* change to ccMessage

* remove vim command artefact

---------

Co-authored-by: Thomas Roehl <thomas.roehl@fau.de>
Co-authored-by: exterr2f <Robert.Externbrink@rub.de>
Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com>

* Fix artifacts of not done cc-lib switch

* Fix artifacts in netstat collector of not done cc-lib switch

* Change to cc-lib (#135)

* Change to ccMessage from cc-lib

* Remove local development path

* Use receiver, sinks, ccLogger and ccConfig from cc-lib

* Fix ccLogger import path

* Update CI

* Delete mountpoint when it vanishes, not just its data (#137)

---------

Co-authored-by: Michael Panzlaff <michael.panzlaff@fau.de>
Co-authored-by: brinkcoder <Robert.Externbrink@ruhr-uni-bochum.de>
Co-authored-by: exterr2f <Robert.Externbrink@rub.de>
2025-04-16 13:38:11 +02:00

191 lines
4.4 KiB
Go

package collectors
import (
"bufio"
"bytes"
"encoding/json"
"errors"
"fmt"
"io"
"log"
"os/exec"
"strconv"
"strings"
"time"
cclog "github.com/ClusterCockpit/cc-lib/ccLogger"
lp "github.com/ClusterCockpit/cc-lib/ccMessage"
)
const IPMISENSORS_PATH = `ipmi-sensors`
type IpmiCollector struct {
metricCollector
config struct {
ExcludeDevices []string `json:"exclude_devices"`
IpmitoolPath string `json:"ipmitool_path"`
IpmisensorsPath string `json:"ipmisensors_path"`
}
ipmitool string
ipmisensors string
}
func (m *IpmiCollector) Init(config json.RawMessage) error {
// Check if already initialized
if m.init {
return nil
}
m.name = "IpmiCollector"
m.setup()
m.parallel = true
m.meta = map[string]string{
"source": m.name,
"group": "IPMI",
}
// default path to IPMI tools
m.config.IpmitoolPath = "ipmitool"
m.config.IpmisensorsPath = "ipmi-sensors"
if len(config) > 0 {
err := json.Unmarshal(config, &m.config)
if err != nil {
return err
}
}
// Check if executables ipmitool or ipmisensors are found
p, err := exec.LookPath(m.config.IpmitoolPath)
if err == nil {
command := exec.Command(p)
err := command.Run()
if err != nil {
cclog.ComponentError(m.name, fmt.Sprintf("Failed to execute %s: %v", p, err.Error()))
m.ipmitool = ""
} else {
m.ipmitool = p
}
}
p, err = exec.LookPath(m.config.IpmisensorsPath)
if err == nil {
command := exec.Command(p)
err := command.Run()
if err != nil {
cclog.ComponentError(m.name, fmt.Sprintf("Failed to execute %s: %v", p, err.Error()))
m.ipmisensors = ""
} else {
m.ipmisensors = p
}
}
if len(m.ipmitool) == 0 && len(m.ipmisensors) == 0 {
return errors.New("no usable IPMI reader found")
}
m.init = true
return nil
}
func (m *IpmiCollector) readIpmiTool(cmd string, output chan lp.CCMessage) {
// Setup ipmitool command
command := exec.Command(cmd, "sensor")
stdout, _ := command.StdoutPipe()
errBuf := new(bytes.Buffer)
command.Stderr = errBuf
// start command
if err := command.Start(); err != nil {
cclog.ComponentError(
m.name,
fmt.Sprintf("readIpmiTool(): Failed to start command \"%s\": %v", command.String(), err),
)
return
}
// Read command output
scanner := bufio.NewScanner(stdout)
for scanner.Scan() {
lv := strings.Split(scanner.Text(), "|")
if len(lv) < 3 {
continue
}
v, err := strconv.ParseFloat(strings.TrimSpace(lv[1]), 64)
if err == nil {
name := strings.ToLower(strings.Replace(strings.TrimSpace(lv[0]), " ", "_", -1))
unit := strings.TrimSpace(lv[2])
if unit == "Volts" {
unit = "Volts"
} else if unit == "degrees C" {
unit = "degC"
} else if unit == "degrees F" {
unit = "degF"
} else if unit == "Watts" {
unit = "Watts"
}
y, err := lp.NewMessage(name, map[string]string{"type": "node"}, m.meta, map[string]interface{}{"value": v}, time.Now())
if err == nil {
y.AddMeta("unit", unit)
output <- y
}
}
}
// Wait for command end
if err := command.Wait(); err != nil {
errMsg, _ := io.ReadAll(errBuf)
cclog.ComponentError(
m.name,
fmt.Sprintf("readIpmiTool(): Failed to wait for the end of command \"%s\": %v\n", command.String(), err),
)
cclog.ComponentError(m.name, fmt.Sprintf("readIpmiTool(): command stderr: \"%s\"\n", strings.TrimSpace(string(errMsg))))
return
}
}
func (m *IpmiCollector) readIpmiSensors(cmd string, output chan lp.CCMessage) {
command := exec.Command(cmd, "--comma-separated-output", "--sdr-cache-recreate")
command.Wait()
stdout, err := command.Output()
if err != nil {
log.Print(err)
return
}
ll := strings.Split(string(stdout), "\n")
for _, line := range ll {
lv := strings.Split(line, ",")
if len(lv) > 3 {
v, err := strconv.ParseFloat(lv[3], 64)
if err == nil {
name := strings.ToLower(strings.Replace(lv[1], " ", "_", -1))
y, err := lp.NewMessage(name, map[string]string{"type": "node"}, m.meta, map[string]interface{}{"value": v}, time.Now())
if err == nil {
if len(lv) > 4 {
y.AddMeta("unit", lv[4])
}
output <- y
}
}
}
}
}
func (m *IpmiCollector) Read(interval time.Duration, output chan lp.CCMessage) {
// Check if already initialized
if !m.init {
return
}
if len(m.config.IpmitoolPath) > 0 {
m.readIpmiTool(m.config.IpmitoolPath, output)
} else if len(m.config.IpmisensorsPath) > 0 {
m.readIpmiSensors(m.config.IpmisensorsPath, output)
}
}
func (m *IpmiCollector) Close() {
m.init = false
}