* Use channels, add a metric router, split up configuration and use extended version of Influx line protocol internally * Use central timer for collectors and router. Add expressions to router * Add expression to router config * Update entry points * Start with README * Update README for CCMetric * Formatting * Update README.md * Add README for MultiChanTicker * Add README for MultiChanTicker * Update README.md * Add README to metric router * Update main README * Remove SinkEntity type * Update README for sinks * Update go files * Update README for receivers * Update collectors README * Update collectors README * Use seperate page per collector * Fix for tempstat page * Add docs for customcmd collector * Add docs for ipmistat collector * Add docs for topprocs collector * Update customCmdMetric.md * Use seconds when calculating LIKWID metrics * Add IB metrics ib_recv_pkts and ib_xmit_pkts * Drop domain part of host name * Updated to latest stable version of likwid * Define source code dependencies in Makefile * Add GPFS / IBM Spectrum Scale collector * Add vet and staticcheck make targets * Add vet and staticcheck make targets * Avoid go vet warning: struct field tag `json:"..., omitempty"` not compatible with reflect.StructTag.Get: suspicious space in struct tag value struct field tag `json:"...", omitempty` not compatible with reflect.StructTag.Get: key:"value" pairs not separated by spaces * Add sample collector to README.md * Add CPU frequency collector * Avoid staticcheck warning: redundant return statement * Avoid staticcheck warning: unnecessary assignment to the blank identifier * Simplified code * Add CPUFreqCollectorCpuinfo a metric collector to measure the current frequency of the CPUs as obtained from /proc/cpuinfo Only measure on the first hyperthread * Add collector for NFS clients * Move publication of metrics into Flush() for NatsSink * Update GitHub actions * Refactoring * Avoid vet warning: Println arg list ends with redundant newline * Avoid vet warning struct field commands has json tag but is not exported * Avoid vet warning: return copies lock value. * Corrected typo * Refactoring * Add go sources in internal/... * Bad separator in Makefile * Fix Infiniband collector Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
142 lines
3.2 KiB
Go
142 lines
3.2 KiB
Go
package collectors
|
|
|
|
import (
|
|
"encoding/json"
|
|
"errors"
|
|
"log"
|
|
"os"
|
|
"os/exec"
|
|
"strconv"
|
|
"strings"
|
|
"time"
|
|
lp "github.com/ClusterCockpit/cc-metric-collector/internal/ccMetric"
|
|
)
|
|
|
|
const IPMITOOL_PATH = `/usr/bin/ipmitool`
|
|
const IPMISENSORS_PATH = `/usr/sbin/ipmi-sensors`
|
|
|
|
type IpmiCollectorConfig struct {
|
|
ExcludeDevices []string `json:"exclude_devices"`
|
|
IpmitoolPath string `json:"ipmitool_path"`
|
|
IpmisensorsPath string `json:"ipmisensors_path"`
|
|
}
|
|
|
|
type IpmiCollector struct {
|
|
metricCollector
|
|
tags map[string]string
|
|
matches map[string]string
|
|
config IpmiCollectorConfig
|
|
}
|
|
|
|
func (m *IpmiCollector) Init(config json.RawMessage) error {
|
|
m.name = "IpmiCollector"
|
|
m.setup()
|
|
m.meta = map[string]string{"source": m.name, "group": "IPMI"}
|
|
if len(config) > 0 {
|
|
err := json.Unmarshal(config, &m.config)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
}
|
|
_, err1 := os.Stat(m.config.IpmitoolPath)
|
|
_, err2 := os.Stat(m.config.IpmisensorsPath)
|
|
if err1 != nil {
|
|
m.config.IpmitoolPath = ""
|
|
}
|
|
if err2 != nil {
|
|
m.config.IpmisensorsPath = ""
|
|
}
|
|
if err1 != nil && err2 != nil {
|
|
return errors.New("No IPMI reader found")
|
|
}
|
|
m.init = true
|
|
return nil
|
|
}
|
|
|
|
func (m *IpmiCollector) readIpmiTool(cmd string, output chan lp.CCMetric) {
|
|
command := exec.Command(cmd, "sensor")
|
|
command.Wait()
|
|
stdout, err := command.Output()
|
|
if err != nil {
|
|
log.Print(err)
|
|
return
|
|
}
|
|
|
|
ll := strings.Split(string(stdout), "\n")
|
|
|
|
for _, line := range ll {
|
|
lv := strings.Split(line, "|")
|
|
if len(lv) < 3 {
|
|
continue
|
|
}
|
|
v, err := strconv.ParseFloat(strings.Trim(lv[1], " "), 64)
|
|
if err == nil {
|
|
name := strings.ToLower(strings.Replace(strings.Trim(lv[0], " "), " ", "_", -1))
|
|
unit := strings.Trim(lv[2], " ")
|
|
if unit == "Volts" {
|
|
unit = "Volts"
|
|
} else if unit == "degrees C" {
|
|
unit = "degC"
|
|
} else if unit == "degrees F" {
|
|
unit = "degF"
|
|
} else if unit == "Watts" {
|
|
unit = "Watts"
|
|
}
|
|
|
|
y, err := lp.New(name, map[string]string{"type": "node"}, m.meta, map[string]interface{}{"value": v}, time.Now())
|
|
if err == nil {
|
|
y.AddMeta("unit", unit)
|
|
output <- y
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
func (m *IpmiCollector) readIpmiSensors(cmd string, output chan lp.CCMetric) {
|
|
|
|
command := exec.Command(cmd, "--comma-separated-output", "--sdr-cache-recreate")
|
|
command.Wait()
|
|
stdout, err := command.Output()
|
|
if err != nil {
|
|
log.Print(err)
|
|
return
|
|
}
|
|
|
|
ll := strings.Split(string(stdout), "\n")
|
|
|
|
for _, line := range ll {
|
|
lv := strings.Split(line, ",")
|
|
if len(lv) > 3 {
|
|
v, err := strconv.ParseFloat(lv[3], 64)
|
|
if err == nil {
|
|
name := strings.ToLower(strings.Replace(lv[1], " ", "_", -1))
|
|
y, err := lp.New(name, map[string]string{"type": "node"}, m.meta, map[string]interface{}{"value": v}, time.Now())
|
|
if err == nil {
|
|
if len(lv) > 4 {
|
|
y.AddMeta("unit", lv[4])
|
|
}
|
|
output <- y
|
|
}
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
func (m *IpmiCollector) Read(interval time.Duration, output chan lp.CCMetric) {
|
|
if len(m.config.IpmitoolPath) > 0 {
|
|
_, err := os.Stat(m.config.IpmitoolPath)
|
|
if err == nil {
|
|
m.readIpmiTool(m.config.IpmitoolPath, output)
|
|
}
|
|
} else if len(m.config.IpmisensorsPath) > 0 {
|
|
_, err := os.Stat(m.config.IpmisensorsPath)
|
|
if err == nil {
|
|
m.readIpmiSensors(m.config.IpmisensorsPath, output)
|
|
}
|
|
}
|
|
}
|
|
|
|
func (m *IpmiCollector) Close() {
|
|