cc-metric-collector/collectors/likwid/groups/silvermont/TLB_INSTR.txt
2021-03-25 14:47:10 +01:00

28 lines
765 B
Plaintext

SHORT L1 Instruction TLB miss rate/ratio
EVENTSET
FIXC0 INSTR_RETIRED_ANY
FIXC1 CPU_CLK_UNHALTED_CORE
FIXC2 CPU_CLK_UNHALTED_REF
PMC0 PAGE_WALKS_ITLB_COUNT
PMC1 PAGE_WALKS_ITLB_CYCLES
METRICS
Runtime (RDTSC) [s] time
Runtime unhalted [s] FIXC1*inverseClock
Clock [MHz] 1.E-06*(FIXC1/FIXC2)/inverseClock
CPI FIXC1/FIXC0
L1 ITLB misses PMC0
L1 ITLB miss rate PMC0/FIXC0
L1 ITLB miss duration [Cyc] PMC1/PMC0
LONG
Formulas:
L1 ITLB misses = PAGE_WALKS_ITLB_COUNT
L1 ITLB miss rate = PAGE_WALKS_ITLB_COUNT / INSTR_RETIRED_ANY
L1 ITLB miss duration [Cyc] = PAGE_WALKS_ITLB_CYCLES / PAGE_WALKS_ITLB_COUNT
-
The ITLB miss rates gives a measure how often a TLB miss occurred
per instruction. The duration measures the time in cycles how long a walk did take.