cc-metric-collector/collectors/likwid/groups/nehalemEX/L2.txt
2021-03-25 14:47:10 +01:00

41 lines
1.4 KiB
Plaintext

SHORT L2 cache bandwidth in MBytes/s
EVENTSET
FIXC0 INSTR_RETIRED_ANY
FIXC1 CPU_CLK_UNHALTED_CORE
FIXC2 CPU_CLK_UNHALTED_REF
PMC0 L1D_REPL
PMC1 L1D_M_EVICT
PMC2 L1I_MISSES
METRICS
Runtime (RDTSC) [s] time
Runtime unhalted [s] FIXC1*inverseClock
Clock [MHz] 1.E-06*(FIXC1/FIXC2)/inverseClock
CPI FIXC1/FIXC0
L2D load bandwidth [MBytes/s] 1.0E-06*PMC0*64.0/time
L2D load data volume [GBytes] 1.0E-09*PMC0*64.0
L2D evict bandwidth [MBytes/s] 1.0E-06*PMC1*64.0/time
L2D evict data volume [GBytes] 1.0E-09*PMC1*64.0
L2 bandwidth [MBytes/s] 1.0E-06*(PMC0+PMC1+PMC2)*64.0/time
L2 data volume [GBytes] 1.0E-09*(PMC0+PMC1+PMC2)*64.0
LONG
Formulas:
L2D load bandwidth [MBytes/s] = 1.0E-06*L1D_REPL*64.0/time
L2D load data volume [GBytes] = 1.0E-09*L1D_REPL*64.0
L2D evict bandwidth [MBytes/s] = 1.0E-06*L1D_M_EVICT*64.0/time
L2D evict data volume [GBytes] = 1.0E-09*L1D_M_EVICT*64.0
L2 bandwidth [MBytes/s] = 1.0E-06*(L1D_REPL+L1D_M_EVICT+L1I_MISSES)*64/time
L2 data volume [GBytes] = 1.0E-09*(L1D_REPL+L1D_M_EVICT+L1I_MISSES)*64
-
Profiling group to measure L2 cache bandwidth. The bandwidth is
computed by the number of cache line allocated in the L1 and the
number of modified cache lines evicted from the L1. Also reports on
total data volume transferred between L2 and L1 cache.
Note that this bandwidth also includes data transfers due to a
write allocate load on a store miss in L1 and traffic caused by misses in the
L1 instruction cache.