cc-metric-collector/collectors/likwid/groups/ivybridge/UOPS_ISSUE.txt
2021-03-25 14:47:10 +01:00

32 lines
1.0 KiB
Plaintext

SHORT UOPs issueing
EVENTSET
FIXC0 INSTR_RETIRED_ANY
FIXC1 CPU_CLK_UNHALTED_CORE
FIXC2 CPU_CLK_UNHALTED_REF
PMC0 UOPS_ISSUED_USED_CYCLES
PMC1 UOPS_ISSUED_STALL_CYCLES
PMC2 CPU_CLOCK_UNHALTED_TOTAL_CYCLES
PMC3:EDGEDETECT UOPS_ISSUED_STALL_CYCLES
METRICS
Runtime (RDTSC) [s] time
Runtime unhalted [s] FIXC1*inverseClock
Clock [MHz] 1.E-06*(FIXC1/FIXC2)/inverseClock
CPI FIXC1/FIXC0
Used cycles ratio [%] 100*PMC0/PMC2
Unused cycles ratio [%] 100*PMC1/PMC2
Avg stall duration [cycles] PMC1/PMC3:EDGEDETECT
LONG
Formulas:
Used cycles ratio [%] = 100*UOPS_ISSUED_USED_CYCLES/CPU_CLK_UNHALTED_CORE
Unused cycles ratio [%] = 100*UOPS_ISSUED_STALL_CYCLES/CPU_CLK_UNHALTED_CORE
Avg stall duration [cycles] = UOPS_ISSUED_STALL_CYCLES/UOPS_ISSUED_STALL_CYCLES:EDGEDETECT
-
This performance group returns the ratios of used and unused cycles regarding
the issue stage in the pipeline. Used cycles are all cycles where uOPs are
issued while unused cycles refer to pipeline stalls. Moreover, the group
calculates the average stall duration in cycles.