cc-metric-collector/internal/metricRouter
Thomas Gruber 7840de7b82
Merge develop branch into main (#123)
* Add cpu_used (all-cpu_idle) to CpustatCollector

* Update cc-metric-collector.init

* Allow selection of timestamp precision in HttpSink

* Add comment about precision requirement for cc-metric-store

* Fix for API changes in gofish@v0.15.0

* Update requirements to latest version

* Read sensors through redfish

* Update golang toolchain to 1.21

* Remove stray error check

* Update main config in configuration.md

* Update Release action to use golang 1.22 stable release, no golang RPMs anymore

* Update runonce action to use golang 1.22 stable release, no golang RPMs anymore

* Update README.md

Use right JSON type in configuration

* Update sink's README

* Test whether ipmitool or ipmi-sensors can be executed without errors

* Little fixes to the prometheus sink (#115)

* Add uint64 to float64 cast option

* Add prometheus sink to the list of available sinks

* Add aggregated counters by gpu for nvlink errors

---------

Co-authored-by: Michael Schwarz <schwarz@uni-paderborn.de>

* Ccmessage migration (#119)

* Add cpu_used (all-cpu_idle) to CpustatCollector

* Update cc-metric-collector.init

* Allow selection of timestamp precision in HttpSink

* Add comment about precision requirement for cc-metric-store

* Fix for API changes in gofish@v0.15.0

* Update requirements to latest version

* Read sensors through redfish

* Update golang toolchain to 1.21

* Remove stray error check

* Update main config in configuration.md

* Update Release action to use golang 1.22 stable release, no golang RPMs anymore

* Update runonce action to use golang 1.22 stable release, no golang RPMs anymore

* Switch to CCMessage for all files.

---------

Co-authored-by: Holger Obermaier <Holger.Obermaier@kit.edu>
Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>

* Switch to ccmessage also for latest additions in nvidiaMetric

* New Message processor (#118)

* Add cpu_used (all-cpu_idle) to CpustatCollector

* Update cc-metric-collector.init

* Allow selection of timestamp precision in HttpSink

* Add comment about precision requirement for cc-metric-store

* Fix for API changes in gofish@v0.15.0

* Update requirements to latest version

* Read sensors through redfish

* Update golang toolchain to 1.21

* Remove stray error check

* Update main config in configuration.md

* Update Release action to use golang 1.22 stable release, no golang RPMs anymore

* Update runonce action to use golang 1.22 stable release, no golang RPMs anymore

* New message processor to check whether a message should be dropped or manipulate it in flight

* Create a copy of message before manipulation

---------

Co-authored-by: Holger Obermaier <Holger.Obermaier@kit.edu>
Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>

* Update collector's Makefile and go.mod/sum files

* Use message processor in router, all sinks and all receivers

* Add support for credential file (NKEY) to NATS sink and receiver

* Fix JSON keys in message processor configuration

* Update docs for message processor, router and the default router config file

* Add link to expr syntax and fix regex matching docs

* Update sample collectors

* Minor style change in collector manager

* Some helpers for ccTopology

* LIKWID collector: write log owner change only once

* Fix for metrics without units and reduce debugging messages for messageProcessor

* Use shorted hostname for hostname added by router

* Define default port for NATS

* CPUstat collector: only add unit for applicable metrics

* Add precision option to all sinks using Influx's encoder

* Add message processor to all sink documentation

* Add units to documentation of cpustat collector

---------

Co-authored-by: Holger Obermaier <Holger.Obermaier@kit.edu>
Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
Co-authored-by: oscarminus <me@oscarminus.de>
Co-authored-by: Michael Schwarz <schwarz@uni-paderborn.de>
2024-12-19 23:00:14 +01:00
..
metricCache.go Merge develop branch into main (#123) 2024-12-19 23:00:14 +01:00
metricRouter.go Merge develop branch into main (#123) 2024-12-19 23:00:14 +01:00
README.md Merge develop branch into main (#123) 2024-12-19 23:00:14 +01:00

CC Metric Router

The CCMetric router sits in between the collectors and the sinks and can be used to add and remove tags to/from traversing [CCMessages](https://pkg.go.dev/github.com/ClusterCockpit/cc-energy-manager@v0.0.0-20240919152819-92a17f2da4f7/pkg/cc-message.

Configuration

Note: Use the message processor configuration with option process_messages.

{
    "num_cache_intervals" : 1,
    "interval_timestamp" : true,
    "hostname_tag" : "hostname",
    "max_forward" : 50,
    "process_messages": {
      "see": "pkg/messageProcessor/README.md"
    },
    "add_tags" : [
        {
            "key" : "cluster",
            "value" : "testcluster",
            "if" : "*"
        },
        {
            "key" : "test",
            "value" : "testing",
            "if" : "name == 'temp_package_id_0'"
        }
    ],
    "delete_tags" : [
        {
            "key" : "unit",
            "value" : "*",
            "if" : "*"
        }
    ],
    "interval_aggregates" : [
        {
            "name" : "temp_cores_avg",
            "if" : "match('temp_core_%d+', metric.Name())",
            "function" : "avg(values)",
            "tags" : {
                "type" : "node"
            },
            "meta" : {
                "group": "IPMI",
                "unit": "degC",
                "source": "TempCollector"
            }
        }
    ],
    "drop_metrics" : [
        "not_interesting_metric_at_all"
    ],
    "drop_metrics_if" : [
        "match('temp_core_%d+', metric.Name())"
    ],
    "rename_metrics" : {
        "metric_12345" : "mymetric"
    },
    "normalize_units" : true,
    "change_unit_prefix" : {
      "mem_used" : "G",
      "mem_total" : "G"
    }
}

There are three main options add_tags, delete_tags and interval_timestamp. add_tags and delete_tags are lists consisting of dicts with key, value and if. The value can be omitted in the delete_tags part as it only uses the key for removal. The interval_timestamp setting means that a unique timestamp is applied to all metrics traversing the router during an interval.

Note: Use the message processor configuration (option process_messages) instead of add_tags, delete_tags, drop_metrics, drop_metrics_if, rename_metrics, normalize_units and change_unit_prefix. These options are deprecated and will be removed in future versions. Until then, they are added to the message processor.

Processing order in the router

  • Add the hostname_tag tag (if sent by collectors or cache)
  • If interval_timestamp == true, change time of metrics
  • Check if metric should be dropped (drop_metrics and drop_metrics_if)
  • Add tags from add_tags
  • Delete tags from del_tags
  • Rename metric based on rename_metrics and store old name as oldname in meta information
  • Add tags from add_tags (if you used the new name in the if condition)
  • Delete tags from del_tags (if you used the new name in the if condition)
  • Send to sinks
  • Move to cache (if num_cache_intervals > 0)

The interval_timestamp option

The collectors' Read() functions are not called simultaneously and therefore the metrics gathered in an interval can have different timestamps. If you want to avoid that and have a common timestamp (the beginning of the interval), set this option to true and the MetricRouter sets the time.

The num_cache_intervals option

If the MetricRouter should buffer metrics of intervals in a MetricCache, this option specifies the number of past intervals that should be kept. If num_cache_intervals = 0, the cache is disabled. With num_cache_intervals = 1, only the metrics of the last interval are buffered.

A num_cache_intervals > 0 is required to use the interval_aggregates option.

The hostname_tag option

By default, the router tags metrics with the hostname for all locally created metrics. The default tag name is hostname, but it can be changed if your organization wants anything else

The max_forward option

Every time the router receives a metric through any of the channels, it tries to directly read up to max_forward metrics from the same channel. This was done as the router thread would go to sleep and wake up with every arriving metric. The default are 50 metrics at once and max_forward needs to greater than 1.

The rename_metrics option

deprecated

In the ClusterCockpit world we specified a set of standard metrics. Since some collectors determine the metric names based on files, execuables and libraries, they might change from system to system (or installation to installtion, OS to OS, ...). In order to get the common names, you can rename incoming metrics before sending them to the sink. If the metric name matches the oldname, it is changed to newname

{
  "oldname" : "newname",
  "clock_mhz" : "clock"
}

Conditional manipulation of tags (add_tags and del_tags)

deprecated

Common config format:

{
    "key" : "test",
    "value" : "testing",
    "if" : "name == 'temp_package_id_0'"
}

The del_tags option

deprecated

The collectors are free to add whatever key=value pair to the metric tags (although the usage of tags should be minimized). If you want to delete a tag afterwards, you can do that. When the if condition matches on a metric, the key is removed from the metric's tags.

If you want to remove a tag for all metrics, use the condition wildcard *. The value field can be omitted in the del_tags case.

Never delete tags:

  • hostname
  • type
  • type-id

The add_tags option

deprecated

In some cases, metrics should be tagged or an existing tag changed based on some condition. This can be done in the add_tags section. When the if condition evaluates to true, the tag key is added or gets changed to the new value.

If the CCMetric name is equal to temp_package_id_0, it adds an additional tag test=testing to the metric.

For this metric, a more useful example would be:

[
  {
    "key" : "type",
    "value" : "socket",
    "if" : "name == 'temp_package_id_0'"
  },
  {
    "key" : "type-id",
    "value" : "0",
    "if" : "name == 'temp_package_id_0'"
  },
]

The metric temp_package_id_0 corresponds to the tempature of the first CPU socket (=package). With the above configuration, the tags would reflect that because commonly the TempCollector submits only node metrics.

In order to match all metrics, you can use *, so in order to add a flag per default. This is useful to attached system-specific tags like cluster=testcluster:

{
    "key" : "cluster",
    "value" : "testcluster",
    "if" : "*"
}

Dropping metrics

In some cases, you want to drop a metric and don't get it forwarded to the sinks. There are two options based on the required specification:

  • Based only on the metric name -> drop_metrics section
  • An evaluable condition with more overhead -> drop_metrics_if section

The drop_metrics section

deprecated

The argument is a list of metric names. No futher checks are performed, only a comparison of the metric name

{
  "drop_metrics" : [
      "drop_metric_1",
      "drop_metric_2"
  ]
}

The example drops all metrics with the name drop_metric_1 and drop_metric_2.

The drop_metrics_if section

deprecated

This option takes a list of evaluable conditions and performs them one after the other on all metrics incoming from the collectors and the metric cache (aka interval_aggregates).

{
  "drop_metrics_if" : [
      "match('drop_metric_%d+', name)",
      "match('cpu', type) && type-id == 0"
  ]
}

The first line is comparable with the example in drop_metrics, it drops all metrics starting with drop_metric_ and ending with a number. The second line drops all metrics of the first hardware thread (not recommended)

Manipulating the metric units

The normalize_units option

deprecated

The cc-metric-collector tries to read the data from the system as it is reported. If available, it tries to read the metric unit from the system as well (e.g. from /proc/meminfo). The problem is that, depending on the source, the metric units are named differently. Just think about byte, Byte, B, bytes, ... The cc-units package provides us a normalization option to use the same metric unit name for all metrics. It this option is set to true, all unit meta tags are normalized.

The change_unit_prefix section

deprecated

It is often the case that metrics are reported by the system using a rather outdated unit prefix (like /proc/meminfo still uses kByte despite current memory sizes are in the GByte range). If you want to change the prefix of a unit, you can do that with the help of cc-units. The setting works on the metric name and requires the new prefix for the metric. The cc-units package determines the scaling factor.

Aggregate metric values of the current interval with the interval_aggregates option

Note: interval_aggregates works only if num_cache_intervals > 0 and is experimental

In some cases, you need to derive new metrics based on the metrics arriving during an interval. This can be done in the interval_aggregates section. The logic is similar to the other metric manipulation and filtering options. A cache stores all metrics that arrive during an interval. At the beginning of the next interval, the list of metrics is submitted to the MetricAggregator. It derives new metrics and submits them back to the MetricRouter, so they are sent in the next interval but have the timestamp of the previous interval beginning.

"interval_aggregates" : [
  {
    "name" : "new_metric_name",
    "if" : "match('sub_metric_%d+', metric.Name())",
    "function" : "avg(values)",
    "tags" : {
      "key" : "value",
      "type" : "node"
    },
    "meta" : {
      "key" : "value",
      "group": "IPMI",
      "unit": "<copy>",
    }
  }
]

The above configuration, collects all metric values for metrics evaluating if to true. Afterwards it calculates the average avg of the values (list of all metrics' field value) and creates a new CCMetric with the name new_metric_name and adds the tags in tags and the meta information in meta. The special value <copy> searches the input metrics and copies the value of the first match of key to the new CCMetric.

If you are not interested in the input metrics sub_metric_%d+ at all, you can add the same condition used here to the drop_metrics_if section to drop them.

Use cases for interval_aggregates:

  • Combine multiple metrics of the a collector to a new one like the MemstatCollector does it for mem_used)):
  {
    "name" : "mem_used",
    "if" : "source == 'MemstatCollector'",
    "function" : "sum(mem_total) - (sum(mem_free) + sum(mem_buffers) + sum(mem_cached))",
    "tags" : {
      "type" : "node"
    },
    "meta" : {
      "group": "<copy>",
      "unit": "<copy>",
      "source": "<copy>"
    }
  }

Order of operations

The router performs the above mentioned options in a specific order. In order to get the logic you want for a specific metric, it is crucial to know the processing order:

  • Add the hostname tag (c)
  • Manipulate the timestamp to the interval timestamp (c,r)
  • Drop metrics based on drop_metrics and drop_metrics_if (c,r)
  • Add tags based on add_tags (c,r)
  • Delete tags based on del_tags (c,r)
  • Rename metric based on rename_metric (c,r)
    • Add tags based on add_tags to still work if the configuration uses the new name (c,r)
    • Delete tags based on del_tags to still work if the configuration uses the new name (c,r)
  • Normalize units when normalize_units is set (c,r)
  • Convert unit prefix based on change_unit_prefix (c,r)

Legend:

  • 'c' if metric is coming from a collector
  • 'r' if metric is coming from a receiver