SHORT L2 cache bandwidth in MBytes/s
|
|
|
|
EVENTSET
|
|
PMC0 INST_RETIRED
|
|
PMC1 CPU_CYCLES
|
|
PMC2 L1D_CACHE_REFILL
|
|
PMC3 L1D_CACHE_WB
|
|
PMC4 L1I_CACHE_REFILL
|
|
|
|
|
|
METRICS
|
|
Runtime (RDTSC) [s] time
|
|
Clock [MHz] 1.E-06*PMC1/time
|
|
CPI PMC1/PMC0
|
|
L2D load bandwidth [MBytes/s] 1.0E-06*PMC2*64.0/time
|
|
L2D load data volume [GBytes] 1.0E-09*PMC2*64.0
|
|
L2D evict bandwidth [MBytes/s] 1.0E-06*PMC3*64.0/time
|
|
L2D evict data volume [GBytes] 1.0E-09*PMC3*64.0
|
|
L2I load bandwidth [MBytes/s] 1.0E-06*PMC4*64.0/time
|
|
L2I load data volume [GBytes] 1.0E-09*PMC4*64.0
|
|
L2 bandwidth [MBytes/s] 1.0E-06*(PMC2+PMC3+PMC4)*64.0/time
|
|
L2 data volume [GBytes] 1.0E-09*(PMC2+PMC3+PMC4)*64.0
|
|
|
|
LONG
|
|
Formulas:
|
|
CPI = CPU_CYCLES/INST_RETIRED
|
|
L2D load bandwidth [MBytes/s] = 1.0E-06*L1D_CACHE_REFILL*64.0/time
|
|
L2D load data volume [GBytes] = 1.0E-09*L1D_CACHE_REFILL*64.0
|
|
L2D evict bandwidth [MBytes/s] = 1.0E-06*L1D_CACHE_WB*64.0/time
|
|
L2D evict data volume [GBytes] = 1.0E-09*L1D_CACHE_WB*64.0
|
|
L2I load bandwidth [MBytes/s] = 1.0E-06*L1I_CACHE_REFILL*64.0/time
|
|
L2I load data volume [GBytes] = 1.0E-09*L1I_CACHE_REFILL*64.0
|
|
L2 bandwidth [MBytes/s] = 1.0E-06*(L1D_CACHE_REFILL+L1D_CACHE_WB+L1I_CACHE_REFILL)*64.0/time
|
|
L2 data volume [GBytes] = 1.0E-09*(L1D_CACHE_REFILL+L1D_CACHE_WB+L1I_CACHE_REFILL)*64.0
|
|
-
|
|
Profiling group to measure L2 cache bandwidth. The bandwidth is computed by the
|
|
number of cacheline loaded from the L2 to the L1 data cache and the writebacks from
|
|
the L1 data cache to the L2 cache. The group also outputs total data volume transfered between
|
|
L2 and L1. Note that this bandwidth also includes data transfers due to a write
|
|
allocate load on a store miss in L1 and cachelines transfered it the instruction
|
|
cache.
|