mirror of
https://github.com/ClusterCockpit/cc-metric-collector.git
synced 2024-12-27 23:59:05 +01:00
33 lines
1.2 KiB
Plaintext
33 lines
1.2 KiB
Plaintext
SHORT L2 cache bandwidth in MBytes/s
|
|
|
|
EVENTSET
|
|
PMC0 PM_L2_ST
|
|
PMC2 PM_LD_MISS_L1
|
|
PMC4 PM_RUN_INST_CMPL
|
|
PMC5 PM_RUN_CYC
|
|
|
|
|
|
METRICS
|
|
Runtime (RDTSC) [s] time
|
|
CPI PMC5/PMC4
|
|
L2D load bandwidth [MBytes/s] 1.0E-06*(PMC2/2)*128.0/time
|
|
L2D load data volume [GBytes] 1.0E-09*(PMC2/2)*128.0
|
|
L2D store bandwidth [MBytes/s] 1.0E-06*(PMC0/2)*128.0/time
|
|
L2D store data volume [GBytes] 1.0E-09*(PMC0/2)*128.0
|
|
L2 bandwidth [MBytes/s] 1.0E-06*((PMC0+PMC2)/2)*128.0/time
|
|
L2 data volume [GBytes] 1.0E-09*((PMC0+PMC2)/2)*128.0
|
|
|
|
LONG
|
|
Formulas:
|
|
CPI = PM_RUN_CYC/PM_RUN_INST_CMPL
|
|
L2D load bandwidth [MBytes/s] = 1.0E-06*(PM_DATA_FROM_L2/2)*128.0/time
|
|
L2D load data volume [GBytes] = 1.0E-09*(PM_DATA_FROM_L2/2)*128.0
|
|
L2D store bandwidth [MBytes/s] = 1.0E-06*(PM_ST_CMPL/2)*128.0/time
|
|
L2D store data volume [GBytes] = 1.0E-09*(PM_ST_CMPL/2)*128.0
|
|
L2 bandwidth [MBytes/s] = 1.0E-06*((PM_DATA_FROM_L2 + PM_ST_CMPL))*128.0/time
|
|
L2 data volume [GBytes] = 1.0E-09*((PM_DATA_FROM_L2 + PM_ST_CMPL))*128.0
|
|
-
|
|
Profiling group to measure L2 cache bandwidth. The bandwidth is computed by the
|
|
number of cacheline loaded from the L2 to the L1 data cache. There is currently no
|
|
event to get the evicted data volume.
|