8d85bd53f1
* Cleanup: Remove unused code * Use Golang duration parser for 'interval' and 'duration' in main config * Update handling of LIKWID headers. Download only if not already present in the system. Fixes #73 * Units with cc-units (#64) * Add option to normalize units with cc-unit * Add unit conversion to router * Add option to change unit prefix in the router * Add to MetricRouter README * Add order of operations in router to README * Use second add_tags/del_tags only if metric gets renamed * Skip disks in DiskstatCollector that have size=0 * Check readability of sensor files in TempCollector * Fix for --once option * Rename `cpu` type to `hwthread` (#69) * Rename 'cpu' type to 'hwthread' to avoid naming clashes with MetricStore and CC-Webfrontend * Collectors in parallel (#74) * Provide info to CollectorManager whether the collector can be executed in parallel with others * Split serial and parallel collectors. Read in parallel first * Update NvidiaCollector with new metrics, MIG and NvLink support (#75) * CC topology module update (#76) * Rename CPU to hardware thread, write some comments * Do renaming in other parts * Remove CpuList and SocketList function from metricCollector. Available in ccTopology * Option to use MIG UUID as subtype-id in NvidiaCollector * Option to use MIG slice name as subtype-id in NvidiaCollector * MetricRouter: Fix JSON in README * Fix for Github Action to really use the selected version * Remove Ganglia installation in runonce Action and add Go 1.18 * Fix daemon options in init script * Add separate go.mod files to use it with deprecated 1.16 * Minor updates for Makefiles * fix string comparison * AMD ROCm SMI collector (#77) * Add collector for AMD ROCm SMI metrics * Fix import path * Fix imports * Remove Board Number * store GPU index explicitly * Remove board number from description * Use http instead of ftp to download likwid * Fix serial number in rocmCollector * Improved http sink (#78) * automatic flush in NatsSink * tweak default options of HttpSink * shorter cirt. section and retries for HttpSink * fix error handling * Remove file added by mistake. * Use http instead of ftp to download likwid * Fix serial number in rocmCollector Co-authored-by: Thomas Roehl <thomas.roehl@fau.de> Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com> Co-authored-by: Lou <lou.knauer@gmx.de> |
||
---|---|---|
.. | ||
gangliaCommon.go | ||
gangliaSink.go | ||
gangliaSink.md | ||
httpSink.go | ||
httpSink.md | ||
influxAsyncSink.go | ||
influxAsyncSink.md | ||
influxSink.go | ||
influxSink.md | ||
libgangliaSink.go | ||
libgangliaSink.md | ||
metricSink.go | ||
natsSink.go | ||
natsSink.md | ||
prometheusSink.go | ||
prometheusSink.md | ||
README.md | ||
sampleSink.go | ||
sinkManager.go | ||
stdoutSink.go | ||
stdoutSink.md |
CCMetric sinks
This folder contains the SinkManager and sink implementations for the cc-metric-collector.
Available sinks:
stdout
: Print all metrics tostdout
,stderr
or a filehttp
: Send metrics to an HTTP server as POST requestsinfluxdb
: Send metrics to an InfluxDB databaseinfluxasync
: Send metrics to an InfluxDB database with non-blocking write APInats
: Publish metrics to the NATS network overlay systemganglia
: Publish metrics in the Ganglia Monitoring System using thegmetric
CLI toollibganglia
: Publish metrics in the Ganglia Monitoring System directly usinglibganglia.so
prometeus
: Publish metrics for the Prometheus Monitoring System
Configuration
The configuration file for the sinks is a list of configurations. The type
field in each specifies which sink to initialize.
[
"mystdout" : {
"type" : "stdout",
"meta_as_tags" : false
},
"metricstore" : {
"type" : "http",
"host" : "localhost",
"port" : "4123",
"database" : "ccmetric",
"password" : "<jwt token>"
}
]
Contributing own sinks
A sink contains five functions and is derived from the type sink
:
Init(name string, config json.RawMessage) error
Write(point CCMetric) error
Flush() error
Close()
New<Typename>(name string, config json.RawMessage) (Sink, error)
(calls theInit()
function)
The data structures should be set up in Init()
like opening a file or server connection. The Write()
function writes/sends the data. For non-blocking sinks, the Flush()
method tells the sink to drain its internal buffers. The Close()
function should tear down anything created in Init()
.
Finally, the sink needs to be registered in the sinkManager.go
. There is a list of sinks called AvailableSinks
which is a map (sink_type_string
-> pointer to sink interface
). Add a new entry with a descriptive name and the new sink.
Sample sink
package sinks
import (
"encoding/json"
"log"
lp "github.com/ClusterCockpit/cc-metric-collector/internal/ccMetric"
)
type SampleSinkConfig struct {
defaultSinkConfig // defines JSON tags for 'name' and 'meta_as_tags'
}
type SampleSink struct {
sink // declarate 'name' and 'meta_as_tags'
config StdoutSinkConfig // entry point to the SampleSinkConfig
}
// Initialize the sink by giving it a name and reading in the config JSON
func (s *SampleSink) Init(name string, config json.RawMessage) error {
s.name = fmt.Sprintf("SampleSink(%s)", name) // Always specify a name here
// Read in the config JSON
if len(config) > 0 {
err := json.Unmarshal(config, &s.config)
if err != nil {
return err
}
}
return nil
}
// Code to submit a single CCMetric to the sink
func (s *SampleSink) Write(point lp.CCMetric) error {
log.Print(point)
return nil
}
// If the sink uses batched sends internally, you can tell to flush its buffers
func (s *SampleSink) Flush() error {
return nil
}
// Close sink: close network connection, close files, close libraries, ...
func (s *SampleSink) Close() {}
// New function to create a new instance of the sink
func NewSampleSink(name string, config json.RawMessage) (Sink, error) {
s := new(SampleSink)
err := s.Init(name, config)