	* Add cpu_used (all-cpu_idle) to CpustatCollector * Update to line-protocol/v2 * Update runonce.yml with Golang 1.20 * Update fsnotify in LIKWID Collector * Use not a pointer to line-protocol.Encoder * Simplify Makefile * Use only as many arguments as required * Allow sum function to handle non float types * Allow values to be a slice of type float64, float32, int, int64, int32, bool * Use generic function to simplify code * Add missing case for type []int32 * Use generic function to compute minimum * Use generic function to compute maximum * Use generic function to compute average * Add error value to sumAnyType * Use generic function to compute median * For older versions of go slices is not part of the installation * Remove old entries from go.sum * Use simpler sort function * Compute metrics ib_total and ib_total_pkts * Add aggregated metrics. Add missing units * Update likwidMetric.go Fixes a potential bug when `fsnotify.NewWatcher()` fails with an error * Completly avoid memory allocations in infinibandMetric read() * Fixed initialization: Initalization and measurements should run in the same thread --------- Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
		
			
				
	
	
	
		
			1.1 KiB
		
	
	
	
	
	
	
	
			
		
		
	
	
			1.1 KiB
		
	
	
	
	
	
	
	
ibstat collector
  "ibstat": {
    "exclude_devices": [
      "mlx4"
    ],
    "send_abs_values": true,
    "send_derived_values": true
  }
The ibstat collector includes all Infiniband devices that can be
found below /sys/class/infiniband/ and where any of the ports provides a
LID file (/sys/class/infiniband/<dev>/ports/<port>/lid)
The devices can be filtered with the exclude_devices option in the configuration.
For each found LID the collector reads data through the sysfs files below /sys/class/infiniband/<device>. (See: https://www.kernel.org/doc/Documentation/ABI/stable/sysfs-class-infiniband)
Metrics:
- ib_recv
- ib_xmit
- ib_recv_pkts
- ib_xmit_pkts
- ib_total = ib_recv + ib_xmit(if- send_total_values == true)
- ib_total_pkts = ib_recv_pkts + ib_xmit_pkts(if- send_total_values == true)
- ib_recv_bw(if- send_derived_values == true)
- ib_xmit_bw(if- send_derived_values == true)
- ib_recv_pkts_bw(if- send_derived_values == true)
- ib_xmit_pkts_bw(if- send_derived_values == true)
The collector adds a device tag to all metrics