mirror of
https://github.com/ClusterCockpit/cc-metric-collector.git
synced 2025-11-05 02:55:06 +01:00
Merge current development version into main (#48)
* DiskstatCollector: cast part_max_used metric to int * Add uint types to GangliaSink and LibgangliaSink * Use new sink instances to allow multiple of same sink type * Update sink README and SampleSink * Use new receiver instances to allow multiple of same receiver type * Fix metric scope in likwid configuration script * Mention likwid config script in LikwidCollector README * Refactor: Embed Init() into New() function * Refactor: Embed Init() into New() function * Fix: MetricReceiver uses uninitialized values, when initialization fails * Use Ganglia configuration (#44) * Copy all metric configurations from original Ganglia code * Use metric configurations from Ganglia for some metrics * Format value string also for known metrics * Numa-aware memstat collector (#45) * Add samples for collectors, sinks and receivers * Ping InfluxDB server after connecting to recognize faulty connections * Add sink for Prometheus monitoring system (#46) * Add sink for Prometheus monitoring system * Add prometheus sink to README * Add scraper for Prometheus clients (#47) Co-authored-by: Holger Obermaier <holgerob@gmx.de> Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
This commit is contained in:
@@ -13,14 +13,14 @@ import (
|
||||
const SINK_MAX_FORWARD = 50
|
||||
|
||||
// Map of all available sinks
|
||||
var AvailableSinks = map[string]Sink{
|
||||
"influxdb": new(InfluxSink),
|
||||
"stdout": new(StdoutSink),
|
||||
"nats": new(NatsSink),
|
||||
"http": new(HttpSink),
|
||||
"ganglia": new(GangliaSink),
|
||||
"influxasync": new(InfluxAsyncSink),
|
||||
"libganglia": new(LibgangliaSink),
|
||||
var AvailableSinks = map[string]func(name string, config json.RawMessage) (Sink, error){
|
||||
"ganglia": NewGangliaSink,
|
||||
"libganglia": NewLibgangliaSink,
|
||||
"stdout": NewStdoutSink,
|
||||
"nats": NewNatsSink,
|
||||
"influxdb": NewInfluxSink,
|
||||
"influxasync": NewInfluxAsyncSink,
|
||||
"http": NewHttpSink,
|
||||
}
|
||||
|
||||
// Metric collector manager data structure
|
||||
@@ -149,8 +149,7 @@ func (sm *sinkManager) AddOutput(name string, rawConfig json.RawMessage) error {
|
||||
cclog.ComponentError("SinkManager", "SKIP", name, "unknown sink:", sinkConfig.Type)
|
||||
return err
|
||||
}
|
||||
s := AvailableSinks[sinkConfig.Type]
|
||||
err = s.Init(rawConfig)
|
||||
s, err := AvailableSinks[sinkConfig.Type](name, rawConfig)
|
||||
if err != nil {
|
||||
cclog.ComponentError("SinkManager", "SKIP", s.Name(), "initialization failed:", err.Error())
|
||||
return err
|
||||
|
||||
Reference in New Issue