* Remove go-toolkit as build requirement for RPM builds if run in CI * Remove condition around BuildRequires and use go-toolkit for RPM builds * use go-toolkit for RPM builds * Install go-toolkit to fulfill build requirements for RPM * Add golang-race for UBI9 and Alma9 * Fix wrongly named packages * Fix wrongly named packages * Fix Release part * Fix Release part * Fix documentation of RAPL collector * Mark all JSON config fields of message processor as omitempty * Generate HUGO inputs out of Markdown files * Check creation of CCMessage in NATS receiver * Use CCMessage FromBytes instead of Influx's decoder * Rename 'process_message' to 'process_messages' in metricRouter config This makes the behavior more consistent with the other modules, which have their MessageProcessor named 'process_messages'. This most likely was just a typo. * Add optional interface alias in netstat (#130) * Check creation of CCMessage in NATS receiver * add optional interface aliases for netstatMetric * small fix --------- Co-authored-by: Thomas Roehl <thomas.roehl@fau.de> Co-authored-by: exterr2f <Robert.Externbrink@rub.de> Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com> * Fix excluded metrics for diskstat and add exclude_mounts (#131) * Check creation of CCMessage in NATS receiver * fix excluded metrics and add optional mountpoint exclude --------- Co-authored-by: Thomas Roehl <thomas.roehl@fau.de> Co-authored-by: exterr2f <Robert.Externbrink@rub.de> Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com> * Add derived values for nfsiostat (#132) * Check creation of CCMessage in NATS receiver * add derived_values for nfsiostatMetric --------- Co-authored-by: Thomas Roehl <thomas.roehl@fau.de> Co-authored-by: exterr2f <Robert.Externbrink@rub.de> Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com> * Add exclude_devices to iostat (#133) * Check creation of CCMessage in NATS receiver * add exclude_device for iostatMetric * add md file --------- Co-authored-by: Thomas Roehl <thomas.roehl@fau.de> Co-authored-by: exterr2f <Robert.Externbrink@rub.de> Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com> * Add derived_values for numastats (#134) * Check creation of CCMessage in NATS receiver * add derived_values for numastats * change to ccMessage * remove vim command artefact --------- Co-authored-by: Thomas Roehl <thomas.roehl@fau.de> Co-authored-by: exterr2f <Robert.Externbrink@rub.de> Co-authored-by: Thomas Gruber <Thomas.Roehl@googlemail.com> * Fix artifacts of not done cc-lib switch * Fix artifacts in netstat collector of not done cc-lib switch * Change to cc-lib (#135) * Change to ccMessage from cc-lib * Remove local development path * Use receiver, sinks, ccLogger and ccConfig from cc-lib * Fix ccLogger import path * Update CI * Delete mountpoint when it vanishes, not just its data (#137) --------- Co-authored-by: Michael Panzlaff <michael.panzlaff@fau.de> Co-authored-by: brinkcoder <Robert.Externbrink@ruhr-uni-bochum.de> Co-authored-by: exterr2f <Robert.Externbrink@rub.de>
This commit is contained in:
		@@ -3,16 +3,18 @@
 | 
			
		||||
```json
 | 
			
		||||
  "nfsiostat": {
 | 
			
		||||
    "exclude_metrics": [
 | 
			
		||||
      "nfsio_oread"
 | 
			
		||||
      "oread", "pageread"
 | 
			
		||||
    ],
 | 
			
		||||
    "exclude_filesystems" : [
 | 
			
		||||
        "/mnt",
 | 
			
		||||
    "exclude_filesystems": [
 | 
			
		||||
      "/mnt"
 | 
			
		||||
    ],
 | 
			
		||||
    "use_server_as_stype": false
 | 
			
		||||
    "use_server_as_stype": false,
 | 
			
		||||
    "send_abs_values": false,
 | 
			
		||||
    "send_derived_values": true
 | 
			
		||||
  }
 | 
			
		||||
```
 | 
			
		||||
 | 
			
		||||
The `nfsiostat` collector reads data from `/proc/self/mountstats` and outputs a handful **node** metrics for each NFS filesystem. If a metric or filesystem is not required, it can be excluded from forwarding it to the sink.
 | 
			
		||||
The `nfsiostat` collector reads data from `/proc/self/mountstats` and outputs a handful **node** metrics for each NFS filesystem. If a metric or filesystem is not required, it can be excluded from forwarding it to the sink. **Note:** When excluding metrics, you must provide the base metric name (e.g. pageread) without the nfsio_ prefix. This exclusion applies to both absolute and derived values.
 | 
			
		||||
 | 
			
		||||
Metrics:
 | 
			
		||||
* `nfsio_nread`: Bytes transferred by normal `read()` calls
 | 
			
		||||
@@ -24,4 +26,9 @@ Metrics:
 | 
			
		||||
* `nfsio_nfsread`: Bytes transferred for reading from the server
 | 
			
		||||
* `nfsio_nfswrite`: Pages transferred by writing to the server
 | 
			
		||||
 | 
			
		||||
The `nfsiostat` collector adds the mountpoint to the tags as `stype=filesystem,stype-id=<mountpoint>`. If the server address should be used instead of the mountpoint, use the `use_server_as_stype` config setting.
 | 
			
		||||
For each of these, if derived values are enabled, an additional metric is sent with the `_bw` suffix, which represents the rate:
 | 
			
		||||
 | 
			
		||||
  * For normal byte metrics: `unit=bytes/sec`
 | 
			
		||||
  * For page metrics: `unit=4K_pages/s`
 | 
			
		||||
 | 
			
		||||
The `nfsiostat` collector adds the mountpoint to the tags as `stype=filesystem,stype-id=<mountpoint>`. If the server address should be used instead of the mountpoint, use the `use_server_as_stype` config setting.
 | 
			
		||||
 
 | 
			
		||||