Merge latest development changes to main branch (#79)

* Cleanup: Remove unused code

* Use Golang duration parser for 'interval' and 'duration'
 in main config

* Update handling of LIKWID headers. Download only if not already present in the system. Fixes #73

* Units with cc-units (#64)

* Add option to normalize units with cc-unit

* Add unit conversion to router

* Add option to change unit prefix in the router

* Add to MetricRouter README

* Add order of operations in router to README

* Use second add_tags/del_tags only if metric gets renamed

* Skip disks in DiskstatCollector that have size=0

* Check readability of sensor files in TempCollector

* Fix for --once option

* Rename `cpu` type to `hwthread` (#69)

* Rename 'cpu' type to 'hwthread' to avoid naming clashes with MetricStore and CC-Webfrontend

* Collectors in parallel (#74)

* Provide info to CollectorManager whether the collector can be executed in parallel with others

* Split serial and parallel collectors. Read in parallel first

* Update NvidiaCollector with new metrics, MIG and NvLink support (#75)

* CC topology module update (#76)

* Rename CPU to hardware thread, write some comments

* Do renaming in other parts

* Remove CpuList and SocketList function from metricCollector. Available in ccTopology

* Option to use MIG UUID as subtype-id in NvidiaCollector

* Option to use MIG slice name as subtype-id in NvidiaCollector

* MetricRouter: Fix JSON in README

* Fix for Github Action to really use the selected version

* Remove Ganglia installation in runonce Action and add Go 1.18

* Fix daemon options in init script

* Add separate go.mod files to use it with deprecated 1.16

* Minor updates for Makefiles

* fix string comparison

* AMD ROCm SMI collector (#77)

* Add collector for AMD ROCm SMI metrics

* Fix import path

* Fix imports

* Remove Board Number

* store GPU index explicitly

* Remove board number from description

* Use http instead of ftp to download likwid

* Fix serial number in rocmCollector

* Improved http sink (#78)

* automatic flush in NatsSink

* tweak default options of HttpSink

* shorter cirt. section and retries for HttpSink

* fix error handling

* Remove file added by mistake.

* Use http instead of ftp to download likwid

* Fix serial number in rocmCollector

Co-authored-by: Thomas Roehl <thomas.roehl@fau.de>

Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
Co-authored-by: Lou <lou.knauer@gmx.de>
This commit is contained in:
Thomas Gruber
2022-06-08 15:25:40 +02:00
committed by GitHub
parent 186a62a86b
commit 8d85bd53f1
51 changed files with 2097 additions and 705 deletions

View File

@@ -25,7 +25,6 @@ type InfluxAsyncSinkConfig struct {
Password string `json:"password,omitempty"`
Organization string `json:"organization,omitempty"`
SSL bool `json:"ssl,omitempty"`
RetentionPol string `json:"retention_policy,omitempty"`
// Maximum number of points sent to server in single request. Default 5000
BatchSize uint `json:"batch_size,omitempty"`
// Interval, in ms, in which is buffer flushed if it has not been already written (by reaching batch size) . Default 1000ms
@@ -186,12 +185,17 @@ func NewInfluxAsyncSink(name string, config json.RawMessage) (Sink, error) {
return nil, err
}
}
if len(s.config.Host) == 0 ||
len(s.config.Port) == 0 ||
len(s.config.Database) == 0 ||
len(s.config.Organization) == 0 ||
len(s.config.Password) == 0 {
return nil, errors.New("not all configuration variables set required by InfluxAsyncSink")
if len(s.config.Port) == 0 {
return nil, errors.New("Missing port configuration required by InfluxSink")
}
if len(s.config.Database) == 0 {
return nil, errors.New("Missing database configuration required by InfluxSink")
}
if len(s.config.Organization) == 0 {
return nil, errors.New("Missing organization configuration required by InfluxSink")
}
if len(s.config.Password) == 0 {
return nil, errors.New("Missing password configuration required by InfluxSink")
}
// Create lookup map to use meta infos as tags in the output metric
s.meta_as_tags = make(map[string]bool)