Merge latest development changes to main branch (#79)

* Cleanup: Remove unused code

* Use Golang duration parser for 'interval' and 'duration'
 in main config

* Update handling of LIKWID headers. Download only if not already present in the system. Fixes #73

* Units with cc-units (#64)

* Add option to normalize units with cc-unit

* Add unit conversion to router

* Add option to change unit prefix in the router

* Add to MetricRouter README

* Add order of operations in router to README

* Use second add_tags/del_tags only if metric gets renamed

* Skip disks in DiskstatCollector that have size=0

* Check readability of sensor files in TempCollector

* Fix for --once option

* Rename `cpu` type to `hwthread` (#69)

* Rename 'cpu' type to 'hwthread' to avoid naming clashes with MetricStore and CC-Webfrontend

* Collectors in parallel (#74)

* Provide info to CollectorManager whether the collector can be executed in parallel with others

* Split serial and parallel collectors. Read in parallel first

* Update NvidiaCollector with new metrics, MIG and NvLink support (#75)

* CC topology module update (#76)

* Rename CPU to hardware thread, write some comments

* Do renaming in other parts

* Remove CpuList and SocketList function from metricCollector. Available in ccTopology

* Option to use MIG UUID as subtype-id in NvidiaCollector

* Option to use MIG slice name as subtype-id in NvidiaCollector

* MetricRouter: Fix JSON in README

* Fix for Github Action to really use the selected version

* Remove Ganglia installation in runonce Action and add Go 1.18

* Fix daemon options in init script

* Add separate go.mod files to use it with deprecated 1.16

* Minor updates for Makefiles

* fix string comparison

* AMD ROCm SMI collector (#77)

* Add collector for AMD ROCm SMI metrics

* Fix import path

* Fix imports

* Remove Board Number

* store GPU index explicitly

* Remove board number from description

* Use http instead of ftp to download likwid

* Fix serial number in rocmCollector

* Improved http sink (#78)

* automatic flush in NatsSink

* tweak default options of HttpSink

* shorter cirt. section and retries for HttpSink

* fix error handling

* Remove file added by mistake.

* Use http instead of ftp to download likwid

* Fix serial number in rocmCollector

Co-authored-by: Thomas Roehl <thomas.roehl@fau.de>

Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
Co-authored-by: Lou <lou.knauer@gmx.de>
This commit is contained in:
Thomas Gruber
2022-06-08 15:25:40 +02:00
committed by GitHub
parent 186a62a86b
commit 8d85bd53f1
51 changed files with 2097 additions and 705 deletions

View File

@@ -14,39 +14,43 @@ import (
// Map of all available metric collectors
var AvailableCollectors = map[string]MetricCollector{
"likwid": new(LikwidCollector),
"loadavg": new(LoadavgCollector),
"memstat": new(MemstatCollector),
"netstat": new(NetstatCollector),
"ibstat": new(InfinibandCollector),
"lustrestat": new(LustreCollector),
"cpustat": new(CpustatCollector),
"topprocs": new(TopProcsCollector),
"nvidia": new(NvidiaCollector),
"customcmd": new(CustomCmdCollector),
"iostat": new(IOstatCollector),
"diskstat": new(DiskstatCollector),
"tempstat": new(TempCollector),
"ipmistat": new(IpmiCollector),
"gpfs": new(GpfsCollector),
"cpufreq": new(CPUFreqCollector),
"cpufreq_cpuinfo": new(CPUFreqCpuInfoCollector),
"nfs3stat": new(Nfs3Collector),
"nfs4stat": new(Nfs4Collector),
"numastats": new(NUMAStatsCollector),
"beegfs_meta": new(BeegfsMetaCollector),
"beegfs_storage": new(BeegfsStorageCollector),
"likwid": new(LikwidCollector),
"loadavg": new(LoadavgCollector),
"memstat": new(MemstatCollector),
"netstat": new(NetstatCollector),
"ibstat": new(InfinibandCollector),
"lustrestat": new(LustreCollector),
"cpustat": new(CpustatCollector),
"topprocs": new(TopProcsCollector),
"nvidia": new(NvidiaCollector),
"customcmd": new(CustomCmdCollector),
"iostat": new(IOstatCollector),
"diskstat": new(DiskstatCollector),
"tempstat": new(TempCollector),
"ipmistat": new(IpmiCollector),
"gpfs": new(GpfsCollector),
"cpufreq": new(CPUFreqCollector),
"cpufreq_cpuinfo": new(CPUFreqCpuInfoCollector),
"nfs3stat": new(Nfs3Collector),
"nfs4stat": new(Nfs4Collector),
"numastats": new(NUMAStatsCollector),
"beegfs_meta": new(BeegfsMetaCollector),
"beegfs_storage": new(BeegfsStorageCollector),
"rocm_smi": new(RocmSmiCollector),
}
// Metric collector manager data structure
type collectorManager struct {
collectors []MetricCollector // List of metric collectors to use
output chan lp.CCMetric // Output channels
done chan bool // channel to finish / stop metric collector manager
ticker mct.MultiChanTicker // periodically ticking once each interval
duration time.Duration // duration (for metrics that measure over a given duration)
wg *sync.WaitGroup // wait group for all goroutines in cc-metric-collector
config map[string]json.RawMessage // json encoded config for collector manager
collectors []MetricCollector // List of metric collectors to read in parallel
serial []MetricCollector // List of metric collectors to read serially
output chan lp.CCMetric // Output channels
done chan bool // channel to finish / stop metric collector manager
ticker mct.MultiChanTicker // periodically ticking once each interval
duration time.Duration // duration (for metrics that measure over a given duration)
wg *sync.WaitGroup // wait group for all goroutines in cc-metric-collector
config map[string]json.RawMessage // json encoded config for collector manager
collector_wg sync.WaitGroup // internally used wait group for the parallel reading of collector
parallel_run bool // Flag whether the collectors are currently read in parallel
}
// Metric collector manager access functions
@@ -66,6 +70,7 @@ type CollectorManager interface {
// Initialization is done for all configured collectors
func (cm *collectorManager) Init(ticker mct.MultiChanTicker, duration time.Duration, wg *sync.WaitGroup, collectConfigFile string) error {
cm.collectors = make([]MetricCollector, 0)
cm.serial = make([]MetricCollector, 0)
cm.output = nil
cm.done = make(chan bool)
cm.wg = wg
@@ -100,7 +105,11 @@ func (cm *collectorManager) Init(ticker mct.MultiChanTicker, duration time.Durat
continue
}
cclog.ComponentDebug("CollectorManager", "ADD COLLECTOR", collector.Name())
cm.collectors = append(cm.collectors, collector)
if collector.Parallel() {
cm.collectors = append(cm.collectors, collector)
} else {
cm.serial = append(cm.serial, collector)
}
}
return nil
}
@@ -116,6 +125,10 @@ func (cm *collectorManager) Start() {
// Collector manager is done
done := func() {
// close all metric collectors
if cm.parallel_run {
cm.collector_wg.Wait()
cm.parallel_run = false
}
for _, c := range cm.collectors {
c.Close()
}
@@ -130,7 +143,26 @@ func (cm *collectorManager) Start() {
done()
return
case t := <-tick:
cm.parallel_run = true
for _, c := range cm.collectors {
// Wait for done signal or execute the collector
select {
case <-cm.done:
done()
return
default:
// Read metrics from collector c via goroutine
cclog.ComponentDebug("CollectorManager", c.Name(), t)
cm.collector_wg.Add(1)
go func(myc MetricCollector) {
myc.Read(cm.duration, cm.output)
cm.collector_wg.Done()
}(c)
}
}
cm.collector_wg.Wait()
cm.parallel_run = false
for _, c := range cm.serial {
// Wait for done signal or execute the collector
select {
case <-cm.done: