cpustatMetric.go: Use derived values instead of absolute values (#83)
* cpustatMetric.go: Use derived values instead of absolute values The values in /proc/stat are absolute counters related to the boot time of the system. To obtain a utilization of the CPU, the changes in the counters must be derived according to time. To take only the absolute values leads to the fact that changes in the utilization, straight with larger values, do not become visible. * Add new collector for /proc/schedstat The `schedstat` collector reads data from /proc/schedstat and calculates a load value, separated by hwthread. This might be useful to detect bad cpu pinning on shared nodes etc. Co-authored-by: Michael Schwarz <post@michael-schwarz.name>
This commit is contained in:
@@ -37,6 +37,7 @@ var AvailableCollectors = map[string]MetricCollector{
|
||||
"beegfs_meta": new(BeegfsMetaCollector),
|
||||
"beegfs_storage": new(BeegfsStorageCollector),
|
||||
"rocm_smi": new(RocmSmiCollector),
|
||||
"schedstat": new(SchedstatCollector),
|
||||
}
|
||||
|
||||
// Metric collector manager data structure
|
||||
|
Reference in New Issue