Try to use common metric tags across hardware vendors
This commit is contained in:
parent
c938d32629
commit
888db31dbf
@ -122,29 +122,69 @@ func (r *IPMIReceiver) doReadMetric() {
|
|||||||
continue
|
continue
|
||||||
}
|
}
|
||||||
|
|
||||||
|
metric := strings.ToLower(v2[idxType])
|
||||||
name := strings.ToLower(
|
name := strings.ToLower(
|
||||||
strings.Replace(v2[idxName], " ", "_", -1))
|
strings.Replace(v2[idxName], " ", "_", -1))
|
||||||
metric := strings.ToLower(v2[idxType])
|
|
||||||
unit := v2[idxUnits]
|
unit := v2[idxUnits]
|
||||||
if unit == "Watts" {
|
if unit == "Watts" {
|
||||||
|
|
||||||
|
// Power
|
||||||
metric = "power"
|
metric = "power"
|
||||||
} else if metric == "voltage" && unit == "Volts" {
|
name = strings.TrimSuffix(name, "_power")
|
||||||
} else if metric == "temperature" && unit == "degrees C" {
|
name = strings.TrimSuffix(name, "_pwr")
|
||||||
|
name = strings.TrimPrefix(name, "pwr_")
|
||||||
|
} else if metric == "voltage" &&
|
||||||
|
unit == "Volts" {
|
||||||
|
|
||||||
|
// Voltage
|
||||||
|
name = strings.TrimPrefix(name, "volt_")
|
||||||
|
} else if metric == "temperature" &&
|
||||||
|
unit == "degrees C" {
|
||||||
|
|
||||||
|
// Temperature
|
||||||
|
name = strings.TrimSuffix(name, "_temp")
|
||||||
unit = "degC"
|
unit = "degC"
|
||||||
} else if metric == "temperature" && unit == "degrees F" {
|
} else if metric == "temperature" &&
|
||||||
|
unit == "degrees F" {
|
||||||
|
|
||||||
|
// Temperature
|
||||||
|
name = strings.TrimSuffix(name, "_temp")
|
||||||
unit = "degF"
|
unit = "degF"
|
||||||
} else if metric == "fan" && unit == "RPM" {
|
} else if metric == "fan" && unit == "RPM" {
|
||||||
|
|
||||||
|
// Fan speed
|
||||||
metric = "fan_speed"
|
metric = "fan_speed"
|
||||||
} else if metric == "other units based sensor" &&
|
name = strings.TrimSuffix(name, "_tach")
|
||||||
(unit == "unspecified" ||
|
name = strings.TrimPrefix(name, "spd_")
|
||||||
unit == "%") &&
|
} else if (metric == "cooling device" ||
|
||||||
|
metric == "other units based sensor") &&
|
||||||
|
name == "system_air_flow" &&
|
||||||
|
unit == "CFM" {
|
||||||
|
|
||||||
|
// Air flow
|
||||||
|
metric = "air_flow"
|
||||||
|
name = strings.TrimSuffix(name, "_air_flow")
|
||||||
|
unit = "CubicFeetPerMinute"
|
||||||
|
} else if (metric == "processor" ||
|
||||||
|
metric == "other units based sensor") &&
|
||||||
(name == "cpu_utilization" ||
|
(name == "cpu_utilization" ||
|
||||||
name == "io_utilization" ||
|
name == "io_utilization" ||
|
||||||
name == "mem_utilization" ||
|
name == "mem_utilization" ||
|
||||||
name == "sys_utilization") {
|
name == "sys_utilization") &&
|
||||||
|
(unit == "unspecified" ||
|
||||||
|
unit == "%") {
|
||||||
|
|
||||||
|
// Utilization
|
||||||
metric = "utilization"
|
metric = "utilization"
|
||||||
|
name = strings.TrimSuffix(name, "_utilization")
|
||||||
unit = "percent"
|
unit = "percent"
|
||||||
} else {
|
} else {
|
||||||
|
if false {
|
||||||
|
// Debug output for unprocessed metrics
|
||||||
|
fmt.Printf(
|
||||||
|
"host: '%s', metric: '%s', name: '%s', unit: '%s'\n",
|
||||||
|
host, metric, name, unit)
|
||||||
|
}
|
||||||
continue
|
continue
|
||||||
}
|
}
|
||||||
|
|
||||||
|
Loading…