lenovoDensePower: Improve documentation, fix things
Fix energy and time overflow handling. Send the metric as "lenovo_node_power" per default. This should avoid clashes by default. If you want the old behavior, use a router rule to rename the metric.
This commit is contained in:
@@ -41,7 +41,7 @@ func (m *LenovoDensePowerCollector) Init(config json.RawMessage) error {
|
||||
return nil
|
||||
}
|
||||
|
||||
m.name = "LenovoDensePower"
|
||||
m.name = "LenovoDensePowerCollector"
|
||||
if err := m.setup(); err != nil {
|
||||
return fmt.Errorf("%s Init(): setup() call failed: %w", m.name, err)
|
||||
}
|
||||
@@ -80,6 +80,7 @@ func (m *LenovoDensePowerCollector) readEnergy() (float64, time.Time, error) {
|
||||
argv = append(argv, "sudo", "-n")
|
||||
}
|
||||
|
||||
// The Lenovo hardware wants this magic byte string
|
||||
lenovoRequestEnergyMsg := []uint8{0x3a, 0x32, 4, 2, 0, 0, 0}
|
||||
|
||||
argv = append(argv, m.ipmitool, "raw")
|
||||
@@ -109,6 +110,12 @@ func (m *LenovoDensePowerCollector) readEnergy() (float64, time.Time, error) {
|
||||
return 0, time.Unix(0, 0), fmt.Errorf("result must be 14 bytes as specified in the documentation")
|
||||
}
|
||||
|
||||
// data is layed out like this:
|
||||
// data[0 to 1]: FIFO index of value (for debug only)
|
||||
// data[2 to 5]: Integer part of energy in J (little endian)
|
||||
// data[6 to 7]: Fraction part of energy in mJ (little endian)
|
||||
// data[8 to 11]: Integer part of Unix time of measurement in seconds (little endian)
|
||||
// data[12 to 13]: Fraction part of Unix time of measurement in milliseconds (little endian)
|
||||
wholeJoules := (uint32(data[2]) << 0) | (uint32(data[3]) << 8) | (uint32(data[4]) << 16) | (uint32(data[5]) << 24)
|
||||
milliJoules := uint16(data[6]) | (uint16(data[7]) << 8)
|
||||
finalJoules := float64(wholeJoules) + float64(milliJoules)*1e-3
|
||||
@@ -133,16 +140,23 @@ func (m *LenovoDensePowerCollector) Read(interval time.Duration, output chan lp.
|
||||
}
|
||||
|
||||
powerVal := 0.0
|
||||
if energyTime.After(m.energyTimeLast) {
|
||||
energyValDiff := energyVal - m.energyValLast
|
||||
if energyTime.Compare(m.energyTimeLast) != 0 {
|
||||
// Check for overflow
|
||||
energyValDiff := int64(energyVal) - int64(m.energyValLast)
|
||||
if energyVal < m.energyValLast {
|
||||
energyValDiff += int64(0x100000000)
|
||||
}
|
||||
energyTimeDiff := energyTime.Sub(m.energyTimeLast)
|
||||
powerVal = energyValDiff / energyTimeDiff.Seconds()
|
||||
if energyTime.Before(m.energyTimeLast) {
|
||||
energyTimeDiff = energyTimeDiff + 0x100000000 * time.Second
|
||||
}
|
||||
powerVal = float64(energyValDiff) / energyTimeDiff.Seconds()
|
||||
|
||||
m.energyValLast = energyVal
|
||||
m.energyTimeLast = energyTime
|
||||
}
|
||||
|
||||
metric, err := lp.NewMetric("node_power", map[string]string{"type": "node"}, m.meta, powerVal, energyTime)
|
||||
metric, err := lp.NewMetric("lenovo_node_power", map[string]string{"type": "node"}, m.meta, powerVal, energyTime)
|
||||
if err != nil {
|
||||
cclog.ComponentErrorf(m.name, "lp.NewMetric failed: %v", err)
|
||||
return
|
||||
|
||||
@@ -30,10 +30,14 @@ Lenovo ThinkSystem SD665-N V3 | tested, known to work | node + r
|
||||
To test if your system *may* be supported, you can run the following command *at your own risk*:
|
||||
|
||||
```
|
||||
ipmitool raw 58 50 4 2 0 0 0
|
||||
$ ipmitool raw 58 50 4 2 0 0 0
|
||||
c4 00 83 a9 cb d3 a2 03 df db 47 6a d8 01
|
||||
```
|
||||
|
||||
`ipmitool` typically require root to run.
|
||||
Exactly 14 bytes should be returned.
|
||||
In case not or another error occurs your hardware is likely not supported.
|
||||
|
||||
In addition, `ipmitool` typically require root to run.
|
||||
In order to run `cc-metric-collector` without root priviliges, you can enable `use_sudo`.
|
||||
Add a file like this in `/etc/sudoers.d/` to allow `cc-metric-collector` to run the required commands:
|
||||
|
||||
|
||||