cc-metric-collector/collectors/likwid/groups/CLX/PMM.txt

47 lines
1.8 KiB
Plaintext
Raw Normal View History

2021-03-25 14:47:10 +01:00
SHORT Intel Optance DC bandwidth in MBytes/s
EVENTSET
FIXC0 INSTR_RETIRED_ANY
FIXC1 CPU_CLK_UNHALTED_CORE
FIXC2 CPU_CLK_UNHALTED_REF
MBOX0C0 PMM_CMD1_RD
MBOX0C1 PMM_CMD1_WR
MBOX1C0 PMM_CMD1_RD
MBOX1C1 PMM_CMD1_WR
MBOX2C0 PMM_CMD1_RD
MBOX2C1 PMM_CMD1_WR
MBOX3C0 PMM_CMD1_RD
MBOX3C1 PMM_CMD1_WR
MBOX4C0 PMM_CMD1_RD
MBOX4C1 PMM_CMD1_WR
MBOX5C0 PMM_CMD1_RD
MBOX5C1 PMM_CMD1_WR
METRICS
Runtime (RDTSC) [s] time
Runtime unhalted [s] FIXC1*inverseClock
Clock [MHz] 1.E-06*(FIXC1/FIXC2)/inverseClock
CPI FIXC1/FIXC0
PMM read bandwidth [MBytes/s] 1.0E-06*(MBOX0C0+MBOX1C0+MBOX2C0+MBOX3C0+MBOX4C0+MBOX5C0)*64.0/time
PMM read data volume [GBytes] 1.0E-09*(MBOX0C0+MBOX1C0+MBOX2C0+MBOX3C0+MBOX4C0+MBOX5C0)*64.0
PMM write bandwidth [MBytes/s] 1.0E-06*(MBOX0C1+MBOX1C1+MBOX2C1+MBOX3C1+MBOX4C1+MBOX5C1)*64.0/time
PMM write data volume [GBytes] 1.0E-09*(MBOX0C1+MBOX1C1+MBOX2C1+MBOX3C1+MBOX4C1+MBOX5C1)*64.0
PMM bandwidth [MBytes/s] 1.0E-06*(MBOX0C0+MBOX1C0+MBOX2C0+MBOX3C0+MBOX4C0+MBOX5C0+MBOX0C1+MBOX1C1+MBOX2C1+MBOX3C1+MBOX4C1+MBOX5C1)*64.0/time
PMM data volume [GBytes] 1.0E-09*(MBOX0C0+MBOX1C0+MBOX2C0+MBOX3C0+MBOX4C0+MBOX5C0+MBOX0C1+MBOX1C1+MBOX2C1+MBOX3C1+MBOX4C1+MBOX5C1)*64.0
LONG
Formulas:
PMM read bandwidth [MBytes/s] = 1.0E-06*(SUM(MBOXxC0))*64.0/runtime
PMM read data volume [GBytes] = 1.0E-09*(SUM(MBOXxC0))*64.0
PMM write bandwidth [MBytes/s] = 1.0E-06*(SUM(MBOXxC1))*64.0/runtime
PMM write data volume [GBytes] = 1.0E-09*(SUM(MBOXxC1))*64.0
PMM bandwidth [MBytes/s] = 1.0E-06*(SUM(MBOXxC0)+SUM(MBOXxC1))*64.0/runtime
PMM data volume [GBytes] = 1.0E-09*(SUM(MBOXxC0)+SUM(MBOXxC1))*64.0
-
Profiling group to measure data rate and volume for accesses to Intel Optane DC
persistent memory. The Intel Optance DC devices are handled by the memory