cc-metric-collector/receivers/natsReceiver.go

148 lines
3.3 KiB
Go
Raw Normal View History

2021-05-18 15:15:26 +02:00
package receivers
import (
"encoding/json"
2021-05-18 15:44:42 +02:00
"errors"
Modularize the whole thing (#16) * Use channels, add a metric router, split up configuration and use extended version of Influx line protocol internally * Use central timer for collectors and router. Add expressions to router * Add expression to router config * Update entry points * Start with README * Update README for CCMetric * Formatting * Update README.md * Add README for MultiChanTicker * Add README for MultiChanTicker * Update README.md * Add README to metric router * Update main README * Remove SinkEntity type * Update README for sinks * Update go files * Update README for receivers * Update collectors README * Update collectors README * Use seperate page per collector * Fix for tempstat page * Add docs for customcmd collector * Add docs for ipmistat collector * Add docs for topprocs collector * Update customCmdMetric.md * Use seconds when calculating LIKWID metrics * Add IB metrics ib_recv_pkts and ib_xmit_pkts * Drop domain part of host name * Updated to latest stable version of likwid * Define source code dependencies in Makefile * Add GPFS / IBM Spectrum Scale collector * Add vet and staticcheck make targets * Add vet and staticcheck make targets * Avoid go vet warning: struct field tag `json:"..., omitempty"` not compatible with reflect.StructTag.Get: suspicious space in struct tag value struct field tag `json:"...", omitempty` not compatible with reflect.StructTag.Get: key:"value" pairs not separated by spaces * Add sample collector to README.md * Add CPU frequency collector * Avoid staticcheck warning: redundant return statement * Avoid staticcheck warning: unnecessary assignment to the blank identifier * Simplified code * Add CPUFreqCollectorCpuinfo a metric collector to measure the current frequency of the CPUs as obtained from /proc/cpuinfo Only measure on the first hyperthread * Add collector for NFS clients * Move publication of metrics into Flush() for NatsSink * Update GitHub actions * Refactoring * Avoid vet warning: Println arg list ends with redundant newline * Avoid vet warning struct field commands has json tag but is not exported * Avoid vet warning: return copies lock value. * Corrected typo * Refactoring * Add go sources in internal/... * Bad separator in Makefile * Fix Infiniband collector Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
2022-01-25 15:37:43 +01:00
"fmt"
"time"
cclog "github.com/ClusterCockpit/cc-metric-collector/pkg/ccLogger"
lp "github.com/ClusterCockpit/cc-metric-collector/pkg/ccMetric"
influx "github.com/influxdata/line-protocol/v2/lineprotocol"
2021-05-18 15:15:26 +02:00
nats "github.com/nats-io/nats.go"
)
Modularize the whole thing (#16) * Use channels, add a metric router, split up configuration and use extended version of Influx line protocol internally * Use central timer for collectors and router. Add expressions to router * Add expression to router config * Update entry points * Start with README * Update README for CCMetric * Formatting * Update README.md * Add README for MultiChanTicker * Add README for MultiChanTicker * Update README.md * Add README to metric router * Update main README * Remove SinkEntity type * Update README for sinks * Update go files * Update README for receivers * Update collectors README * Update collectors README * Use seperate page per collector * Fix for tempstat page * Add docs for customcmd collector * Add docs for ipmistat collector * Add docs for topprocs collector * Update customCmdMetric.md * Use seconds when calculating LIKWID metrics * Add IB metrics ib_recv_pkts and ib_xmit_pkts * Drop domain part of host name * Updated to latest stable version of likwid * Define source code dependencies in Makefile * Add GPFS / IBM Spectrum Scale collector * Add vet and staticcheck make targets * Add vet and staticcheck make targets * Avoid go vet warning: struct field tag `json:"..., omitempty"` not compatible with reflect.StructTag.Get: suspicious space in struct tag value struct field tag `json:"...", omitempty` not compatible with reflect.StructTag.Get: key:"value" pairs not separated by spaces * Add sample collector to README.md * Add CPU frequency collector * Avoid staticcheck warning: redundant return statement * Avoid staticcheck warning: unnecessary assignment to the blank identifier * Simplified code * Add CPUFreqCollectorCpuinfo a metric collector to measure the current frequency of the CPUs as obtained from /proc/cpuinfo Only measure on the first hyperthread * Add collector for NFS clients * Move publication of metrics into Flush() for NatsSink * Update GitHub actions * Refactoring * Avoid vet warning: Println arg list ends with redundant newline * Avoid vet warning struct field commands has json tag but is not exported * Avoid vet warning: return copies lock value. * Corrected typo * Refactoring * Add go sources in internal/... * Bad separator in Makefile * Fix Infiniband collector Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
2022-01-25 15:37:43 +01:00
type NatsReceiverConfig struct {
Type string `json:"type"`
Addr string `json:"address"`
Port string `json:"port"`
Subject string `json:"subject"`
Modularize the whole thing (#16) * Use channels, add a metric router, split up configuration and use extended version of Influx line protocol internally * Use central timer for collectors and router. Add expressions to router * Add expression to router config * Update entry points * Start with README * Update README for CCMetric * Formatting * Update README.md * Add README for MultiChanTicker * Add README for MultiChanTicker * Update README.md * Add README to metric router * Update main README * Remove SinkEntity type * Update README for sinks * Update go files * Update README for receivers * Update collectors README * Update collectors README * Use seperate page per collector * Fix for tempstat page * Add docs for customcmd collector * Add docs for ipmistat collector * Add docs for topprocs collector * Update customCmdMetric.md * Use seconds when calculating LIKWID metrics * Add IB metrics ib_recv_pkts and ib_xmit_pkts * Drop domain part of host name * Updated to latest stable version of likwid * Define source code dependencies in Makefile * Add GPFS / IBM Spectrum Scale collector * Add vet and staticcheck make targets * Add vet and staticcheck make targets * Avoid go vet warning: struct field tag `json:"..., omitempty"` not compatible with reflect.StructTag.Get: suspicious space in struct tag value struct field tag `json:"...", omitempty` not compatible with reflect.StructTag.Get: key:"value" pairs not separated by spaces * Add sample collector to README.md * Add CPU frequency collector * Avoid staticcheck warning: redundant return statement * Avoid staticcheck warning: unnecessary assignment to the blank identifier * Simplified code * Add CPUFreqCollectorCpuinfo a metric collector to measure the current frequency of the CPUs as obtained from /proc/cpuinfo Only measure on the first hyperthread * Add collector for NFS clients * Move publication of metrics into Flush() for NatsSink * Update GitHub actions * Refactoring * Avoid vet warning: Println arg list ends with redundant newline * Avoid vet warning struct field commands has json tag but is not exported * Avoid vet warning: return copies lock value. * Corrected typo * Refactoring * Add go sources in internal/... * Bad separator in Makefile * Fix Infiniband collector Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
2022-01-25 15:37:43 +01:00
}
2021-05-18 15:15:26 +02:00
type NatsReceiver struct {
Modularize the whole thing (#16) * Use channels, add a metric router, split up configuration and use extended version of Influx line protocol internally * Use central timer for collectors and router. Add expressions to router * Add expression to router config * Update entry points * Start with README * Update README for CCMetric * Formatting * Update README.md * Add README for MultiChanTicker * Add README for MultiChanTicker * Update README.md * Add README to metric router * Update main README * Remove SinkEntity type * Update README for sinks * Update go files * Update README for receivers * Update collectors README * Update collectors README * Use seperate page per collector * Fix for tempstat page * Add docs for customcmd collector * Add docs for ipmistat collector * Add docs for topprocs collector * Update customCmdMetric.md * Use seconds when calculating LIKWID metrics * Add IB metrics ib_recv_pkts and ib_xmit_pkts * Drop domain part of host name * Updated to latest stable version of likwid * Define source code dependencies in Makefile * Add GPFS / IBM Spectrum Scale collector * Add vet and staticcheck make targets * Add vet and staticcheck make targets * Avoid go vet warning: struct field tag `json:"..., omitempty"` not compatible with reflect.StructTag.Get: suspicious space in struct tag value struct field tag `json:"...", omitempty` not compatible with reflect.StructTag.Get: key:"value" pairs not separated by spaces * Add sample collector to README.md * Add CPU frequency collector * Avoid staticcheck warning: redundant return statement * Avoid staticcheck warning: unnecessary assignment to the blank identifier * Simplified code * Add CPUFreqCollectorCpuinfo a metric collector to measure the current frequency of the CPUs as obtained from /proc/cpuinfo Only measure on the first hyperthread * Add collector for NFS clients * Move publication of metrics into Flush() for NatsSink * Update GitHub actions * Refactoring * Avoid vet warning: Println arg list ends with redundant newline * Avoid vet warning struct field commands has json tag but is not exported * Avoid vet warning: return copies lock value. * Corrected typo * Refactoring * Add go sources in internal/... * Bad separator in Makefile * Fix Infiniband collector Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
2022-01-25 15:37:43 +01:00
receiver
nc *nats.Conn
meta map[string]string
config NatsReceiverConfig
2021-05-18 15:15:26 +02:00
}
2023-09-18 15:37:52 +02:00
// Start subscribes to the configured NATS subject
// Messages wil be handled by r._NatsReceive
2021-05-18 15:15:26 +02:00
func (r *NatsReceiver) Start() {
cclog.ComponentDebug(r.name, "START")
r.nc.Subscribe(r.config.Subject, r._NatsReceive)
2021-05-18 15:15:26 +02:00
}
2023-09-18 15:37:52 +02:00
// _NatsReceive receives subscribed messages from the NATS server
2021-05-18 15:15:26 +02:00
func (r *NatsReceiver) _NatsReceive(m *nats.Msg) {
d := influx.NewDecoderWithBytes(m.Data)
for d.Next() {
// Decode measurement name
measurement, err := d.Measurement()
if err != nil {
msg := "_NatsReceive: Failed to decode measurement: " + err.Error()
cclog.ComponentError(r.name, msg)
return
}
// Decode tags
tags := make(map[string]string)
for {
key, value, err := d.NextTag()
if err != nil {
msg := "_NatsReceive: Failed to decode tag: " + err.Error()
cclog.ComponentError(r.name, msg)
return
Modularize the whole thing (#16) * Use channels, add a metric router, split up configuration and use extended version of Influx line protocol internally * Use central timer for collectors and router. Add expressions to router * Add expression to router config * Update entry points * Start with README * Update README for CCMetric * Formatting * Update README.md * Add README for MultiChanTicker * Add README for MultiChanTicker * Update README.md * Add README to metric router * Update main README * Remove SinkEntity type * Update README for sinks * Update go files * Update README for receivers * Update collectors README * Update collectors README * Use seperate page per collector * Fix for tempstat page * Add docs for customcmd collector * Add docs for ipmistat collector * Add docs for topprocs collector * Update customCmdMetric.md * Use seconds when calculating LIKWID metrics * Add IB metrics ib_recv_pkts and ib_xmit_pkts * Drop domain part of host name * Updated to latest stable version of likwid * Define source code dependencies in Makefile * Add GPFS / IBM Spectrum Scale collector * Add vet and staticcheck make targets * Add vet and staticcheck make targets * Avoid go vet warning: struct field tag `json:"..., omitempty"` not compatible with reflect.StructTag.Get: suspicious space in struct tag value struct field tag `json:"...", omitempty` not compatible with reflect.StructTag.Get: key:"value" pairs not separated by spaces * Add sample collector to README.md * Add CPU frequency collector * Avoid staticcheck warning: redundant return statement * Avoid staticcheck warning: unnecessary assignment to the blank identifier * Simplified code * Add CPUFreqCollectorCpuinfo a metric collector to measure the current frequency of the CPUs as obtained from /proc/cpuinfo Only measure on the first hyperthread * Add collector for NFS clients * Move publication of metrics into Flush() for NatsSink * Update GitHub actions * Refactoring * Avoid vet warning: Println arg list ends with redundant newline * Avoid vet warning struct field commands has json tag but is not exported * Avoid vet warning: return copies lock value. * Corrected typo * Refactoring * Add go sources in internal/... * Bad separator in Makefile * Fix Infiniband collector Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com>
2022-01-25 15:37:43 +01:00
}
if key == nil {
break
2021-10-04 15:23:43 +02:00
}
tags[string(key)] = string(value)
}
// Decode fields
fields := make(map[string]interface{})
for {
key, value, err := d.NextField()
if err != nil {
msg := "_NatsReceive: Failed to decode field: " + err.Error()
cclog.ComponentError(r.name, msg)
return
}
if key == nil {
break
}
fields[string(key)] = value.Interface()
}
// Decode time stamp
t, err := d.Time(influx.Nanosecond, time.Time{})
if err != nil {
msg := "_NatsReceive: Failed to decode time: " + err.Error()
cclog.ComponentError(r.name, msg)
return
}
y, _ := lp.New(
string(measurement),
tags,
r.meta,
fields,
t,
)
if r.sink != nil {
r.sink <- y
2021-05-18 15:15:26 +02:00
}
}
}
2023-09-18 15:37:52 +02:00
// Close closes the connection to the NATS server
2021-05-18 15:15:26 +02:00
func (r *NatsReceiver) Close() {
if r.nc != nil {
cclog.ComponentDebug(r.name, "CLOSE")
2021-05-18 15:15:26 +02:00
r.nc.Close()
}
}
2023-09-18 15:37:52 +02:00
// NewNatsReceiver creates a new Receiver which subscribes to messages from a NATS server
func NewNatsReceiver(name string, config json.RawMessage) (Receiver, error) {
r := new(NatsReceiver)
r.name = fmt.Sprintf("NatsReceiver(%s)", name)
2023-09-18 15:37:52 +02:00
// Read configuration file, allow overwriting default config
r.config.Addr = "localhost"
r.config.Port = "4222"
if len(config) > 0 {
err := json.Unmarshal(config, &r.config)
if err != nil {
cclog.ComponentError(r.name, "Error reading config:", err.Error())
return nil, err
}
}
if len(r.config.Addr) == 0 ||
len(r.config.Port) == 0 ||
len(r.config.Subject) == 0 {
return nil, errors.New("not all configuration variables set required by NatsReceiver")
}
2023-09-18 15:37:52 +02:00
// Set metadata
r.meta = map[string]string{
"source": r.name,
}
// Connect to NATS server
url := fmt.Sprintf("nats://%s:%s", r.config.Addr, r.config.Port)
cclog.ComponentDebug(r.name, "NewNatsReceiver", url, "Subject", r.config.Subject)
if nc, err := nats.Connect(url); err == nil {
r.nc = nc
} else {
r.nc = nil
return nil, err
}
2023-09-18 15:37:52 +02:00
return r, nil
}