cc-metric-collector/collectors/sampleTimerMetric.go

123 lines
3.8 KiB
Go
Raw Normal View History

package collectors
import (
"encoding/json"
"sync"
"time"
cclog "github.com/ClusterCockpit/cc-metric-collector/pkg/ccLogger"
lp "github.com/ClusterCockpit/cc-metric-collector/pkg/ccMetric"
)
// These are the fields we read from the JSON configuration
type SampleTimerCollectorConfig struct {
Interval string `json:"interval"`
}
// This contains all variables we need during execution and the variables
// defined by metricCollector (name, init, ...)
type SampleTimerCollector struct {
metricCollector
wg sync.WaitGroup // sync group for management
done chan bool // channel for management
meta map[string]string // default meta information
tags map[string]string // default tags
config SampleTimerCollectorConfig // the configuration structure
interval time.Duration // the interval parsed from configuration
ticker *time.Ticker // own timer
output chan lp.CCMetric // own internal output channel
}
func (m *SampleTimerCollector) Init(name string, config json.RawMessage) error {
var err error = nil
// Always set the name early in Init() to use it in cclog.Component* functions
m.name = "SampleTimerCollector"
// This is for later use, also call it early
m.setup()
// Define meta information sent with each metric
// (Can also be dynamic or this is the basic set with extension through AddMeta())
m.meta = map[string]string{"source": m.name, "group": "SAMPLE"}
// Define tags sent with each metric
Merge `develop` branch into `main` (#96) * InfiniBandCollector: Scale raw readings from octets to bytes * Fix clock frequency coming from LikwidCollector and update docs * Build DEB package for Ubuntu 20.04 for releases * Fix memstat collector with numa_stats option * Remove useless prints from MemstatCollector * Replace ioutils with os and io (#87) * Use lower case for error strings in RocmSmiCollector * move maybe-usable-by-other-cc-components to pkg. Fix all files to use the new paths (#88) * Add collector for monitoring the execution of cc-metric-collector itself (#81) * Add collector to monitor execution of cc-metric-collector itself * Register SelfCollector * Fix import paths for moved packages * Check if at least one CPU with frequency information was detected * Correct type: /proc/stats -> /proc/stat * Update README.md * Run ipmitool asynchron. Improved error handling. * Corrected some typos * Add running average power limit (RAPL) metric collector * Add running average power limit (RAPL) metric collector * Do not mess up with the orignal configuration * * Corrected json config in numastatsMetric.md * Added some debug output to numastatsMetric.go * Fixed computing number of physical packages for non continous physical package IDs (e.g. on Ampere Altra Q80-30) * Fix kernel panic for receiver config with missing receiver type * Add receiver to gather remote IPMI sensor metrics * Added config option to add ipmi-sensors command line options * Add documentaion for IPMI receiver * Update to latest version of included go modules * Add go.mod to App dependency * Try to use common metric tags across hardware vendors * Add IPMI metric: current * remove prefix enumeration like 01-... * Add IPMI receiver example configuration to receivers.json * Minimal formating changes * Add hostlist package * Added tests for hostlist Expand() * Use package hostlist to expand a host list * Use package hostlist to expand a host list * Some servers return "ConsumedPowerWatt":65535 instead of "ConsumedPowerWatt":null * Updated to latest package versions * Do not allow unknown fields in JSON configuration file * Add workflow to customize packages to docs * NFS I/O Stats Collector (#91) * Initial version * Delete values for vanished mount points and comments * Fix for Likwid collector (#95) * Run LIKWID in separate thread and check metric type * Change LIKWID collector documentation to use 'type' instead of 'scope' * Re-initialize LIKWID after one read is missing due to lock toggle * Register cc-metric-collector at Zenodo (#93) * Add initial version of Zenodo project file * Orcid ID added * Update .zenodo.json Co-authored-by: Holger Obermaier <holger.obermaier@kit.edu> * Update ipmiMetric.go Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com> Co-authored-by: Holger Obermaier <Holger.Obermaier@kit.edu>
2022-12-14 17:02:39 +01:00
// The 'type' tag is always needed, it defines the granularity of the metric
// node -> whole system
// socket -> CPU socket (requires socket ID as 'type-id' tag)
// cpu -> single CPU hardware thread (requires cpu ID as 'type-id' tag)
m.tags = map[string]string{"type": "node"}
// Read in the JSON configuration
if len(config) > 0 {
err = json.Unmarshal(config, &m.config)
if err != nil {
cclog.ComponentError(m.name, "Error reading config:", err.Error())
return err
}
}
// Parse the read interval duration
m.interval, err = time.ParseDuration(m.config.Interval)
if err != nil {
cclog.ComponentError(m.name, "Error parsing interval:", err.Error())
return err
}
// Storage for output channel
m.output = nil
Merge `develop` branch into `main` (#96) * InfiniBandCollector: Scale raw readings from octets to bytes * Fix clock frequency coming from LikwidCollector and update docs * Build DEB package for Ubuntu 20.04 for releases * Fix memstat collector with numa_stats option * Remove useless prints from MemstatCollector * Replace ioutils with os and io (#87) * Use lower case for error strings in RocmSmiCollector * move maybe-usable-by-other-cc-components to pkg. Fix all files to use the new paths (#88) * Add collector for monitoring the execution of cc-metric-collector itself (#81) * Add collector to monitor execution of cc-metric-collector itself * Register SelfCollector * Fix import paths for moved packages * Check if at least one CPU with frequency information was detected * Correct type: /proc/stats -> /proc/stat * Update README.md * Run ipmitool asynchron. Improved error handling. * Corrected some typos * Add running average power limit (RAPL) metric collector * Add running average power limit (RAPL) metric collector * Do not mess up with the orignal configuration * * Corrected json config in numastatsMetric.md * Added some debug output to numastatsMetric.go * Fixed computing number of physical packages for non continous physical package IDs (e.g. on Ampere Altra Q80-30) * Fix kernel panic for receiver config with missing receiver type * Add receiver to gather remote IPMI sensor metrics * Added config option to add ipmi-sensors command line options * Add documentaion for IPMI receiver * Update to latest version of included go modules * Add go.mod to App dependency * Try to use common metric tags across hardware vendors * Add IPMI metric: current * remove prefix enumeration like 01-... * Add IPMI receiver example configuration to receivers.json * Minimal formating changes * Add hostlist package * Added tests for hostlist Expand() * Use package hostlist to expand a host list * Use package hostlist to expand a host list * Some servers return "ConsumedPowerWatt":65535 instead of "ConsumedPowerWatt":null * Updated to latest package versions * Do not allow unknown fields in JSON configuration file * Add workflow to customize packages to docs * NFS I/O Stats Collector (#91) * Initial version * Delete values for vanished mount points and comments * Fix for Likwid collector (#95) * Run LIKWID in separate thread and check metric type * Change LIKWID collector documentation to use 'type' instead of 'scope' * Re-initialize LIKWID after one read is missing due to lock toggle * Register cc-metric-collector at Zenodo (#93) * Add initial version of Zenodo project file * Orcid ID added * Update .zenodo.json Co-authored-by: Holger Obermaier <holger.obermaier@kit.edu> * Update ipmiMetric.go Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com> Co-authored-by: Holger Obermaier <Holger.Obermaier@kit.edu>
2022-12-14 17:02:39 +01:00
// Management channel for the timer function.
m.done = make(chan bool)
// Create the own ticker
m.ticker = time.NewTicker(m.interval)
// Start the timer loop with return functionality by sending 'true' to the done channel
m.wg.Add(1)
go func() {
select {
case <-m.done:
// Exit the timer loop
cclog.ComponentDebug(m.name, "Closing...")
m.wg.Done()
return
case timestamp := <-m.ticker.C:
// This is executed every timer tick but we have to wait until the first
// Read() to get the output channel
if m.output != nil {
m.ReadMetrics(timestamp)
}
}
}()
// Set this flag only if everything is initialized properly, all required files exist, ...
m.init = true
return err
}
// This function is called at each interval timer tick
func (m *SampleTimerCollector) ReadMetrics(timestamp time.Time) {
// Create a sample metric
value := 1.0
Merge `develop` branch into `main` (#96) * InfiniBandCollector: Scale raw readings from octets to bytes * Fix clock frequency coming from LikwidCollector and update docs * Build DEB package for Ubuntu 20.04 for releases * Fix memstat collector with numa_stats option * Remove useless prints from MemstatCollector * Replace ioutils with os and io (#87) * Use lower case for error strings in RocmSmiCollector * move maybe-usable-by-other-cc-components to pkg. Fix all files to use the new paths (#88) * Add collector for monitoring the execution of cc-metric-collector itself (#81) * Add collector to monitor execution of cc-metric-collector itself * Register SelfCollector * Fix import paths for moved packages * Check if at least one CPU with frequency information was detected * Correct type: /proc/stats -> /proc/stat * Update README.md * Run ipmitool asynchron. Improved error handling. * Corrected some typos * Add running average power limit (RAPL) metric collector * Add running average power limit (RAPL) metric collector * Do not mess up with the orignal configuration * * Corrected json config in numastatsMetric.md * Added some debug output to numastatsMetric.go * Fixed computing number of physical packages for non continous physical package IDs (e.g. on Ampere Altra Q80-30) * Fix kernel panic for receiver config with missing receiver type * Add receiver to gather remote IPMI sensor metrics * Added config option to add ipmi-sensors command line options * Add documentaion for IPMI receiver * Update to latest version of included go modules * Add go.mod to App dependency * Try to use common metric tags across hardware vendors * Add IPMI metric: current * remove prefix enumeration like 01-... * Add IPMI receiver example configuration to receivers.json * Minimal formating changes * Add hostlist package * Added tests for hostlist Expand() * Use package hostlist to expand a host list * Use package hostlist to expand a host list * Some servers return "ConsumedPowerWatt":65535 instead of "ConsumedPowerWatt":null * Updated to latest package versions * Do not allow unknown fields in JSON configuration file * Add workflow to customize packages to docs * NFS I/O Stats Collector (#91) * Initial version * Delete values for vanished mount points and comments * Fix for Likwid collector (#95) * Run LIKWID in separate thread and check metric type * Change LIKWID collector documentation to use 'type' instead of 'scope' * Re-initialize LIKWID after one read is missing due to lock toggle * Register cc-metric-collector at Zenodo (#93) * Add initial version of Zenodo project file * Orcid ID added * Update .zenodo.json Co-authored-by: Holger Obermaier <holger.obermaier@kit.edu> * Update ipmiMetric.go Co-authored-by: Holger Obermaier <40787752+ho-ob@users.noreply.github.com> Co-authored-by: Holger Obermaier <Holger.Obermaier@kit.edu>
2022-12-14 17:02:39 +01:00
// If you want to measure something for a specific amount of time, use interval
// start := readState()
// time.Sleep(interval)
// stop := readState()
// value = (stop - start) / interval.Seconds()
y, err := lp.New("sample_metric", m.tags, m.meta, map[string]interface{}{"value": value}, timestamp)
if err == nil && m.output != nil {
// Send it to output channel if we have a valid channel
m.output <- y
}
}
func (m *SampleTimerCollector) Read(interval time.Duration, output chan lp.CCMetric) {
// Capture output channel
m.output = output
}
func (m *SampleTimerCollector) Close() {
// Send signal to the timer loop to stop it
m.done <- true
// Wait until the timer loop is done
m.wg.Wait()
// Unset flag
m.init = false
}