The `nvidia` collector can be configured to leave out specific devices with the `exclude_devices` option. It takes IDs as supplied to the NVML with `nvmlDeviceGetHandleByIndex()` or the PCI address in NVML format (`%08X:%02X:%02X.0`). Metrics (listed below) that should not be sent to the MetricRouter can be excluded with the `exclude_metrics` option. Commonly only the physical GPUs are monitored. If MIG devices should be analyzed as well, set `process_mig_devices` (adds `stype=mig,stype-id=<mig_index>`). With the options `use_uuid_for_mig_device` and `use_slice_for_mig_device`, the `<mig_index>` can be replaced with the UUID (e.g. `MIG-6a9f7cc8-6d5b-5ce0-92de-750edc4d8849`) or the MIG slice name (e.g. `1g.5gb`).
The metrics sent by the `nvidia` collector use `accelerator` as `type` tag. For the `type-id`, it uses the device handle index by default. With the `use_pci_info_as_type_id` option, the PCI ID is used instead. If both values should be added as tags, activate the `add_pci_info_tag` option. It uses the device handle index as `type-id` and adds the PCI ID as separate `pci_identifier` tag.
Optionally, it is possible to add the UUID, the board part number and the serial to the meta informations. They are not sent to the sinks (if not configured otherwise).