mirror of
https://github.com/ClusterCockpit/cc-backend
synced 2025-07-22 20:41:40 +02:00
fix wrong flag labelling, change to kWh energy calculation
This commit is contained in:
@@ -603,12 +603,13 @@ func (r *JobRepository) UpdateEnergy(
|
||||
|
||||
for _, fp := range sc.EnergyFootprint {
|
||||
if i, err := archive.MetricIndex(sc.MetricConfig, fp); err == nil {
|
||||
// FIXME: Check for unit conversions
|
||||
// Energy: Watts * Time // Power: Energy / Time -> Correct labelling here?
|
||||
if sc.MetricConfig[i].Energy == "power" {
|
||||
// Unit: ( W * s ) / 3600 = Wh ; Rounded to 2 nearest digits
|
||||
energy = math.Round(((LoadJobStat(jobMeta, fp, "avg")*float64(jobMeta.Duration))/3600)*100) / 100
|
||||
} else if sc.MetricConfig[i].Energy == "energy" {
|
||||
// Note: For DB data, calculate and save as kWh
|
||||
// Energy: Power (in Watts) * Time (in Seconds)
|
||||
if sc.MetricConfig[i].Energy == "energy" {
|
||||
// Unit: ( W * s ) / 3600 / 1000 = kWh ; Rounded to 2 nearest digits
|
||||
energy = math.Round(((LoadJobStat(jobMeta, fp, "avg")*float64(jobMeta.Duration))/3600/1000)*100) / 100
|
||||
// Power: Use directly as sum (Or as: [Energy (in Ws) / Time (in s)]
|
||||
} else if sc.MetricConfig[i].Energy == "power" {
|
||||
// This assumes the metric is of aggregation type sum
|
||||
}
|
||||
} else {
|
||||
|
Reference in New Issue